Condition for fault identification
Test condition:
The fault is recognized when the voltage is less than 0.073 V and the resistance is less than 15 ohms.
Potential problem source(s):
- Defect in wiring harness
- Oxygen sensor faulty
Terminal condition: none
Voltage condition:
- None
Temperature condition:
- Engine temperature > 85 °C
Time condition:
- None
Other conditions:
- Engine on
- No additional diagnostic fault codes logged