1.14.1 Strategy: Notes
Principle:
- Sensors that can affect emissions or are used to monitor other component/system are monitored for circuit continuity and short to battery voltage and/or to ground using high and low voltage signal limit.
- Actuators that can affect emissions or are used to monitor other component/system are monitored by power stage voltage check for valid signals.
- For some of sensors or actuators, plausibility checks are included to ensure proper operation of the components.