12 42 510 Replacing battery positive lead (between starter motor and B+ support point) (S54)
Read fault memory. Switch off ignition.
Follow instructions for disconnecting and connecting battery. (See 12 00 ... INSTRUCTIONS FOR DISCONNECTING AND CONNECTING BATTERY )
Disconnect battery negative lead from battery and lay to one side.
Remove reinforcement plate (See 51 71 374 REMOVING AND INSTALLING/REPLACING REINFORCEMENT PLATE ON FRONT AXLE SUPPORT )
Release nut, remove battery positive lead (1) from battery positive terminal.
Tightening torque 12 42 1AZ. See ENGINE ELECTRICAL SYSTEM - TIGHTENING TORQUES article.
Unfasten nut.
Remove battery positive lead (1) from holder.
Unfasten nut.
Installation:
Tightening torque, 12 41 4AZ. See ENGINE ELECTRICAL SYSTEM - TIGHTENING TORQUES article.
Detach battery positive lead from starter motor and remove.
Check stored fault messages.
Now clear the fault memory.