Home >> Audi >> 2024 >> S3 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 156 (Turbocharger, Supercharger (4-Cylinder Direct Injection 2.0L 4V TFSI Engine) (DNVB)) >> 21 Turbocharger, Supercharger >> Charge Air System >> Air Duct Pipe, Removing And Installing >> Left Air Duct Pipe, Removing And Installing >> Removing

Left Air Duct Pipe, Removing And Installing: Removing

WARNING: This page is about a different car, the 2024 Audi A3 Quattro and 2024 Audi A3. However, it is still accessible from the selected car via links, so may be relevant.

-- Remove the air filter housing. Refer to AIR FILTER HOUSING, REMOVING AND INSTALLING .

-- Remove the noise insulation. Refer to OVERVIEW - NOISE INSULATION .

-- Loosen the hose clamps -1 and 2- and remove the air duct hose.

GWWA21-10943Courtesy of AUDI OF AMERICA, LLC

-- If installed, free up the coolant hose/pressure line -3-.

GWWA21-10825Courtesy of AUDI OF AMERICA, LLC

-- Free up the wiring harness -1 and 2- from the air duct pipe.

-- Loosen the hose clamp -4-.

-- Remove the bolts -arrows- and then remove the air duct pipe.

Vehicles with Secondary Air System:

GWWA26-12372Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the connector -1-.

-- Press the release buttons on both sides -arrow- and remove the pressure line -2-.

Continuation for All Vehicles:

-- Remove the air duct pipe.

-- Seal the open lines and connections with clean plugs from the Engine Bung Set:VAS 6122  .