Home >> Audi >> 2023 >> A5 Quattro Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 34 (Air Conditioning (Refrigerant R1234YF Servicing (Ac Service Station)) (Coupe)) >> 87 Air Conditioning >> Working With A/C Service Station >> Pressures, Checking >> Refrigerant Circuit With Ignition Switched On, Checking Pressure >> The refrigerant circuit pressure is lower than indicated in table

The refrigerant circuit pressure is lower than indicated in table

WARNING: This page is about a different variant/trim than selected.

Not enough refrigerant in refrigerant circuit.

-- Determine refrigerant circuit leaks. Refer to LEAKS, FINDING .

-- Check the pressure relief valve. Refer to PRESSURE RELIEF VALVE .

If pressure relief valve has responded: (refer to PRESSURE RELIEF VALVE ):

-- Check the activation of the radiator fan or the radiator fans. use the Vehicle Diagnostic Tester in the "Guided Fault Finding" function of the A/C system.

-- On vehicles with shut-off valves for the refrigerant circuit, check the activation and function of this shut-off valve. use the Vehicle Diagnostic Tester in the "Guided Fault Finding" function of the A/C system (and the battery regulation) and refer to the Refrigerant Circuit (vehicle-specific service information).

-- Check the refrigerant pipes and hoses for cross-section constrictions due to outer damage and inadequate bending radii. Refer to Refrigerant Circuit (vehicle-specific service information) and Refrigerant Circuit (vehicle-specific service information).

-- If no error is determined, clean the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, CLEANING .