LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2023 >> A5 Quattro Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 33 (Air Conditioning (Refrigerant R134A Servicing (Safety Precautions)) (Coupe)) >> 87 Air Conditioning >> Refrigerant Circuit General Information >> Refrigerant Circuit Component Allocation, Influence On High And Low Pressure Sides >> O-Rings

Refrigerant Circuit Component Allocation, Influence On High And Low Pressure Sides: O-Rings

WARNING: This page is about a different variant/trim than selected.

These rings seal off the connection points between individual components of the refrigerant circuit.

Fig 1: Checking O-Ring Seal Diameters
GWWA87-0021Courtesy of AUDI OF AMERICA, LLC

Only O-rings that are resistant to refrigerant R134a and the associated refrigerant oil may be used. Make sure they are original replacement parts.

O-Rings:

-- Always use only once.

-- Make sure diameters -a- and -b- are correct.

-- Coat with refrigerant oil before installing. Refer to Refrigerant Circuit (vehicle-specific repair information) and the appropriate Electronic Parts Information.

NOTE:

The O-ring color coding for refrigerant circuits with R134a has been discontinued. Black and colored O-rings are used. Refer to the appropriate Electronic Parts Information and Refrigerant Circuit (vehicle-specific repair information).