Home >> Audi >> 2023 >> A5 Quattro Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 33 (Air Conditioning (Refrigerant R134A Servicing (Safety Precautions)) (Coupe)) >> 87 Air Conditioning >> Refrigerant Circuit General Information >> Refrigerant Circuit Component Allocation, Influence On High And Low Pressure Sides >> Fluid Collector

Fluid Collector

WARNING: This page is about a different variant/trim than selected.

In some operating conditions (in heat pump operation, for example), the receiver/dryer (on the condenser, for example) is not incorporated into the refrigerant circuit. The fluid collector -B- collects the refrigerant, and stores it temporarily if a certain amount of refrigerant is not needed, and then directs it in an uninterrupted stream to the expansion valve (in front of the evaporator in the heater and A/C unit) or to the heat exchanger in the high-voltage system coolant circuit. Refer to Refrigerant Circuit (vehicle-specific repair information).