Home >> Audi >> 2023 >> A5 Quattro Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 18 (Air Conditioning (Heating, Ventilation And Air Conditioning) (Coupe)) >> 87 Air Conditioning >> Refrigerant Circuit >> Refrigerant Shut-Off Valve -V424-, REMOVING AND INSTALLING >> Removing

Refrigerant Shut-Off Valve -V424-, REMOVING AND INSTALLING: Removing

WARNING: This page is about a different variant/trim than selected.

-- Initiate the A/C system basic setting through the Thermal Management Control Module -J1024- and open the power-activated valves through the stored routine "Extract, evacuate and fill the refrigerant circuit" using the Vehicle Diagnostic Tester.

-- Switch off the ignition.

-- Discharge the refrigerant circuit. Refer to Refrigerant Circuit (Refrigerant R134a Servicing, Refrigerant Circuit, Working with A/C Service Station) or Working with A/C Service Station .

-- Remove the plenum chamber cover. Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .

-- Disconnect the connector -D-.

GWWA87-12673Courtesy of AUDI OF AMERICA, LLC
CAUTION:

Danger or frostbite due to refrigerant coming out under pressure.

Frostbite on the skin and other parts of the body is possible.

- Wear safety gloves.

- Wear protective eyewear.

- Evacuate or drain refrigerant and open the refrigerant circuit immediately.

- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit was not opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.

-- Mark the position of the refrigerant lines -A and E- to the Refrigerant Shut-Off Valve -V424- -G-.

-- Loosen the union nuts -H and F- at the same time counterhold on the Refrigerant Shut-Off Valve -- -G-.

-- Remove the Refrigerant Shut-Off Valve -V424- -G-.