Home >> Audi >> 2023 >> A5 Quattro Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 18 (Air Conditioning (Heating, Ventilation And Air Conditioning) (Coupe)) >> 87 Air Conditioning >> Refrigerant Circuit >> Check Valves In Refrigerant Circuit, Removing And Installing >> Check Valve In Refrigerant Line From Refrigerant Receiver, Removing And Installing >> Installing

Check Valve In Refrigerant Line From Refrigerant Receiver, Removing And Installing: Installing

WARNING: This page is about a different variant/trim than selected.
GWWA87-12627Courtesy of AUDI OF AMERICA, LLC

Install in reverse order of removal and note the following:

-- Replace the O-rings -2-. Refer to SEALS AND GASKETS .

-- If equipped, check the alignment pins -6- on the refrigerant lines for damage and correct seating.

-- Check the routing of the refrigerant lines after attaching. They must be inserted into the provided brackets and must not come in contact with other components.

-- Evacuate and fill the refrigerant circuit. Refer to Refrigerant Circuit (Refrigerant R134a Servicing, Refrigerant Circuit, Working with A/C Service Station) or Working with A/C Service Station .

-- Initiate the basic setting of the A/C system through the Thermal Management Control Module -J1024- and activate the power-controlled valves using one of the routines stored there. "Charge/flush the refrigerant circuit stop routine" using the Vehicle Diagnostic Tester.