LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2023 >> A5 Quattro Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 18 (Air Conditioning (Heating, Ventilation And Air Conditioning) (Coupe)) >> 87 Air Conditioning >> Refrigerant Circuit >> A/C Pressure/Temperature Sensor 2 -G826-, REMOVING AND INSTALLING >> Installing

A/C Pressure/Temperature Sensor 2 -G826-, REMOVING AND INSTALLING: Installing

WARNING: This page is about a different variant/trim than selected.
GWWA87-12628Courtesy of AUDI OF AMERICA, LLC

Install in reverse order of removal and note the following:

-- Replace the O-ring -C- and lightly coat the O-ring with refrigerant oil before installing. Refer to SEALS AND GASKETS .

-- Install the sensor -B- and tighten.

-- Evacuate and fill the refrigerant circuit. Refer to Refrigerant Circuit (Refrigerant R134a Servicing, Refrigerant Circuit, Working with A/C Service Station) or Working with A/C Service Station .

-- Initiate the basic setting of the A/C system through the Thermal Management Control Module -J1024- and activate the power-controlled valves using one of the routines stored there. "Charge/flush the refrigerant circuit stop routine" using the Vehicle Diagnostic Tester .

-- If the A/C Pressure/Temperature Sensor 2 -G826- is replaced, perform an addressing.

Procedure 

-- Connect the Vehicle Diagnostic Tester.

-- Select Diagnostic  mode and start the diagnosis.

-- Select the Test plan  tab.

-- Press the Select custom test  button and select the following tree structure in order:

-- Start the A/C system after charging the refrigerant circuit. Refer to A/C SYSTEM, STARTING AFTER CHARGING REFRIGERANT CIRCUIT .