Overview - Heat Pump Valve Unit: Notes
WARNING: This page is about a different variant/trim than selected.
- Bracket
- Screw
- 8 Nm
- Bolts
- 8 Nm
- Base Plate
- Valve Unit with Wiring Harness
- Label the wiring harness routing before removing
- Pay attention to the correct connector assignment for the wiring harness connectors to the valves in the valve unit. Refer to Connection Diagram Wiring Harness on the Valve Unit .
- The valve unit valves are currently identical in construction. They are assigned through the connector assignment for the wiring harness connectors and are activated accordingly by the Thermal Management Control Module -J1024-. Refer to Wiring Diagram.
- Disassembling and Assembling. Refer to HEAT PUMP VALVE UNIT, DISASSEMBLING AND ASSEMBLING .
- Washer
- Screw
- 8 Nm
- Nuts
- 10 Nm
- Bracket
- Screw
- 8 Nm
- Guide Sleeves
- Rubber Grommet
- Screw
- Guide Sleeves
- Bracket
- Bracket for valve unit and longitudinal member tightening specifications. Refer to Bracket for Valve Unit and Longitudinal Member - Tightening Specifications .
- Rubber Bushing
- Screw
- 10 Nm
- Rubber Bushing
- Guide Sleeve
- Screw
- 8 Nm
- Screw
- 8 Nm
- Coolant Pipe
- Guide Sleeve
- Rubber Grommet
- Base Plate
- Washer
- Nut
- 10 Nm
- Screw
- Screw
- 8 Nm