Battery -A-, DISCONNECTING AND CONNECTING, RS Q3, 0K0: Connecting
-- Disconnect the connector -2- from the Battery Monitoring Control Module -J367- -3-.
-- To connect the battery ground cable terminal clamp to the battery negative terminal "-" by hand tighten the nut -1-.
-- Reconnect the connector to the Battery Monitoring Control Module -J367-.
When the battery is reconnected, the following steps must be performed:
- Activate the power window regulator one-touch up/down function. Refer to the Owner's Manual.
- Check DTC memories of all control modules and delete the displayed entry "Undervoltage" using the Vehicle Diagnostic Tester.
TIP:
After reconnecting the power supply, the ESP warning lamp can only go out after the vehicle has been driven a few meters.
Tightening Specifications
- Refer to OVERVIEW - Battery -A-, RS Q3, 0K0