Battery -A-, DISCONNECTING AND CONNECTING, Q3 (0K3): Connecting
-- Tighten the ground cable -1- on the ground connection.
When the battery is reconnected, the following steps must be performed:
- Activate the power window regulator one-touch up/down function. Refer to the Owner's Manual.
- Check DTC memories of all control modules and delete the displayed entry "Undervoltage" using the Vehicle Diagnostic Tester.
TIP:
After reconnecting the power supply, the ESP warning lamp can only go out after the vehicle has been driven a few meters.
Tightening Specifications
- Refer to OVERVIEW - Battery -A-, Q3 (0K3)