Refrigerant Expansion Valve 2 -N637-, REMOVING AND INSTALLING: Installing
Install in the reverse order of removal while noting the following:
-- Coat the O-ring seals lightly with refrigerant oil before installing. Refer to SEALS AND GASKETS .
-- Check the routing after securing refrigerant lines. They must be inserted in their brackets and must not come into contact with other components.
-- Evacuate and fill the refrigerant circuit. Refer to Refrigerant Circuit or Working with A/C Service Station .
-- Initiate the basic setting of the A/C system using the Thermal Management Control Module -J1024- and activate the electric valves using the routine "Stop routine refrigerant circuit filling/flushing" in the Vehicle Diagnostic Tester
-- Operate the A/C system after charging the refrigerant circuit. Refer to A/C SYSTEM, STARTING AFTER CHARGING REFRIGERANT CIRCUIT .