LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> Q5 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 45 (Hydraulic Components (Brake System)) >> 47 Hydraulic Components >> Vacuum System >> Vacuum System, Checking >> Leak Test

Leak Test

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2022 Audi SQ5, 2022 Audi Q5 e, 2022 Audi Q5, 2021 Audi SQ5, and 2021 Audi Q5 e. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

The average earth atmospheric air pressure at sea level (N. N.) is 1013 mbar and it decreases dramatically at higher altitudes (approximately 100 mbar every 1000 meters higher) Local and time fluctuations also influence the vacuum.

Idling the engine has a negative effect on creating a vacuum.

-- Check all vacuum hoses beforehand for damage (for example, tears or damage caused by animals) and for a secure fit.

-- Connect the : VAS6721  . Refer to BRAKE BOOSTER TESTER, CONNECTING .

-- Open the shut-off valve -A-.

-- Close the shut-off valves -B and C-.

Fig 1: Identifying VAS 6721 Shut-Off Valves
GWWN47-10210Courtesy of AUDI OF AMERICA, LLC

-- Start the warm (above 60 °C) engine and press the accelerator pedal one time quickly (engine speed higher than 2, 000 RPM).

-- Open the shut-off valve -C- to evacuate the brake booster.

Fig 2: Identifying VAS 6721 Shut-Off Valves
GWWN47-10213Courtesy of AUDI OF AMERICA, LLC

-- Turn off the engine.

-- Read the displayed measured value and write it down.

If the drop in vacuum is greater, check for leaks near the...

  1. Brake Booster

    or in the

  2. Check Valve, Vacuum Hoses with Connectors and Vacuum Pump/Intake Manifold

    are present.

The vacuum will drop considerably within a few seconds if there are large leaks.

Vacuum, Checking near Brake Booster:

Fig 3: Identifying VAS 6721 Shut-Off Valves
GWWN47-10214Courtesy of AUDI OF AMERICA, LLC

-- Close the shut-off valve -A- after creating the vacuum to test the brake booster vacuum.

Vacuum, Checking near Check Valve, Vacuum Hoses with Connectors and Vacuum Pump/Intake Manifold

Fig 4: Identifying VAS 6721 Shut-Off Valves
GWWN47-10210Courtesy of AUDI OF AMERICA, LLC

-- Close the shut-off valve -C- after creating the vacuum to check the vacuum system of the : VAS6721  up to the intake manifold or up to the vacuum pump.

Opening the shut-off valve -B- makes it easier to remove the hose connections and the adapter.