Tightening Specifications
The sealing plug, O-ring seal and dryer cartridge must be replaced after every opening of the receiver/dryer.
-- Using the opening, inspect the receiver/dryer on the condenser for debris or for damage on the threaded and sealing surfaces.
Keep the dryer cartridge sealed in its air-tight package as long as possible. Open the package just before installing the dryer cartridge into the condenser. The dryer cartridge absorbs moisture in a very short time and become unusable.
Coat the O-ring seal for the plug with refrigerant oil before installing, refer to REFRIGERANT CIRCUIT SEALS .
-- Remove the dryer cartridge -D- from the package and insert it into the condenser receiver/dryer -E-.
-- Position and install the sealing plug -A-.
-- Evacuating and recharging refrigerant circuit, refer to REFRIGERANT CIRCUIT, DISCHARGING WITH SERVICE STATION or REFRIGERANT CIRCUIT, DISCHARGING WITH SERVICE STATION and REFRIGERANT CIRCUIT, CHARGING WITH SERVICE STATION .
-- Operate the A/C system after filling the refrigerant circuit, refer to A/C SYSTEM, STARTING OPERATION AFTER FILLING REFRIGERANT CIRCUIT .
-- Check the Diagnostic Trouble Code (DTC) memory and erase any displayed entries using the Vehicle Diagnostic Tester in the "Guided Fault Finding" function.