Home >> Audi >> 2017 >> A3 Premium, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 43 (COMMUNICATION (2 Of 2) -- (A3 SEDAN)) >> 91 Communication >> Rearview Camera System >> Rearview Camera System, Calibrating >> Rearview Camera -R189-, Calibrating >> Notes

Rearview Camera -R189-, Calibrating: Notes

WARNING: This page is about a different variant/trim than selected.

Special Tools And Workshop Equipment Required 

-- Establish the requirements. Refer to CALIBRATION REQUIREMENTS .

-- Connect Vehicle Diagnostic Tester.

:VAS6350/1 INSTALLING: 

-- Check which hole circle the rims have.

-- Equip the :VAS6350/1  appropriately.

-- To do so, secure the three wheel bolt adapters in the hole circle to each Calibration Tool - Wheel Center Mountings:VAS6350/1  .

-- Place the paddle on both :VAS6350/1  and secure them using a clamping screw.

-- Place the :VAS6350/1  onto the wheel bolts on the rear wheels.

The :VAS6350/1  are positioned by the "O-rings" in the adapters and secured.

Fig 1: Identifying Wheel Pick-Ups On Wheel Mounting Bolts At Rear Wheels
GWWN94-10685Courtesy of AUDI OF AMERICA, LLC
NOTE:

Attach the :VAS6350/1  onto the wheels so that any installed "anti-theft" wheel bolts are not connected to the :VAS6350/1  .

-- Adjust the paddles with the aid of clamping screw so that they move freely just above the floor. Check the paddles for ease of movement.

-- Install and align the :VAS6350A  . Refer to CALIBRATION UNIT .

Distance Measurement: 

-- Switch on the :VAS6350/2  .

Fig 2: Identifying Display Showing How To Stop Calibration Tool
GWWA91-12101Courtesy of AUDI OF AMERICA, LLC

The display shows how to stop the :VAS6350/2  . Press the corresponding button.

Fig 3: Identifying Front Edge And Rear Edge
GWWA91-12100Courtesy of AUDI OF AMERICA, LLC
  1. Attach with the front edge.
  2. Attach with the rear edge.

-- Hold the :VAS6350/2  -2- flush in the bracket on one side of the calibration board as shown. The :VAS6350/2  -2- must sit securely on the bracket at the same time.

Fig 4: Ensuring Laser Beam From Distance Laser VAS 6350/2 Hits Lower, Enlarged Part Of Paddle
GWWN94-10684Courtesy of AUDI OF AMERICA, LLC

-- Push the measurement button briefly.

The laser switches on.

The laser beam from the :VAS6350/2  -2- must hit the lower, enlarged section of the paddle -1-.

If this is not the case, the paddles must be corrected accordingly via clamping screws on the :VAS6350/1  .

-- Use one hand to secure the :VAS6350/2  in the bracket on the :VAS6350  while the laser beam is visible on the paddle.

-- Then press the measurement button for the distance measurement briefly.

-- Write down the value.

-- Repeat this measurement on the other side of the :VAS6350  in the same way for the rear wheel.

The distance value must be the same on both sides.

If values are not identical:

-- Align the :VAS6350A  long enough so that both sides are identical.

-- When adjusting, make sure the :VAS6350/3A  strikes the center above the Audi rings and that the level indicator remains centered. Adjust if necessary.

Dimension Measurement -H- : 

-- Measure the height of the :VAS6350A  , dimension -H- (top edge platform - floor).

Fig 5: Identifying Height Of Calibration Platform, Dimension -H-
GWWA91-11140Courtesy of AUDI OF AMERICA, LLC

Make sure the :VAS6350/2  is adjusted correctly (attach with front edge).

The display shows how to stop the :VAS6350/2  . Press the corresponding button.

Fig 6: Identifying Front Edge And Rear Edge
GWWA91-12100Courtesy of AUDI OF AMERICA, LLC
  1. Attach with the front edge.
  2. Attach with the rear edge.

Enter the height and distance dimensions into Vehicle Diagnostic Tester in "millimeters".