Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 20 (Charging System (Battery, Starter, Generator) & Cruise Control (Battery & Charging) (Coupe)) >> 27 Starter, Generator And Cruise Control >> Battery, Checking >> Test Sequence >> Checking The Battery - Vehicles Without A Battery Monitoring Control Module -J367- Or Energy Management Control Module -J644-

Checking The Battery - Vehicles Without A Battery Monitoring Control Module -J367- Or Energy Management Control Module -J644-

WARNING: This page is about a different variant/trim than selected.
CAUTION:

It Is Not Possible To Check The Battery Using "Guided Fault Finding  " Through MY 2010 During The Following Procedure, Even If The Vehicle Has A Battery Monitoring Control Module -J367- :

  • A3 From MY 2004 (8P)
  • TT From MY 2007 (8J)
  • R8 From My 2007 (42)
WARNING:

Risk Of Injury. Follow All Warning Messages And Safety Precautions. Refer To WARNINGS AND SAFETY PRECAUTIONS .

Perform The Tests In The Following Sequence:

-- Visual Inspection. Refer To VISUAL INSPECTION .

-- Check The Visual Indicator Color Display (If Equipped). Refer To VISUAL INDICATOR COLOR DISPLAY, CHECKING .

WARNING:

Do Not Check Or Charge A Battery -A- When The Visual Indicator Has >>No Color Or Is Bright Yellow<<. Jump Starting Must Not Be Used!

There Is A Risk Of Explosion During Testing, Charging Or Jump Starting.

These Batteries -A- Must Be Replaced.

NOTE:

The :VAS5097A  Will No Longer Be Used For Warranty Testing. Only The :VAS6161  Is Still Being Used.

-- Battery Test With:

-- Depending On The Result Of The Battery Load Test, "Perform Current Draw Test". Refer To CURRENT DRAW TEST .