Checking internal resistance
WARNING: This page does not describe the selected car, but rather 15 other vehicles, including the 2008 Audi S4, 2008 Audi RS 4, 2008 Audi A4, 2007 Audi S4, and 2007 Audi RS 4. However, it is still accessible from the selected car via links, so may be relevant.
- Connect hand multimeter V.A.G 1526 A or V.A.G 1526 B for resistance measurement as follows.
| Leak detection pump (LDP) Terminal | Specified value |
|---|---|
| - 1 - + - 3 - | 640 to 720 Ω |
| - 2 - + - 3 - | 15 to 17 Ω |
If specifications are not obtained:
- Replace Leak Detection Pump (LDP) V144 → Leak Detection Pump (LDP) V144 , removing and installing .
If specified values are achieved:
- Check voltage supply of leak detection pump Checking voltage supply .