Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 527 (Charging System & Cruise Control System (Starter, Generator & Cruise Control) (Sedan)) >> 27 Starter, Generator And Cruise Control >> Battery, Charging >> Battery Charger VAS5095A >> Battery Charger VAS5095A MAINTENANCE CHARGING

Battery Charger VAS5095A MAINTENANCE CHARGING

WARNING: This page does not describe the selected car, but rather 18 other vehicles, including the 2016 Audi S4, 2016 Audi A4 Quattro, 2016 Audi A4, 2015 Audi S4, and 2015 Audi A4 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
WARNING:

Risk of injury. Follow all warning messages and safety precautions. Refer to WARNINGS AND SAFETY PRECAUTIONS .

WARNING:

Do not check or charge a Battery -A- when the visual indicator has >>no color or is bright yellow<<. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

In maintenance charging, the Battery Charger VAS5095A provides safe charging and preserves the charge of the Battery -A-.

Procedure 

-- Proceed as if charging the Battery -A-. Refer to BATTERY, CHARGING WITH Battery Charger VAS5095A .

If the Battery -A- is discharged by an electrical consumer during maintenance charging, the Battery Charger VAS5095A automatically supplies the appropriate charge.

Maintenance charging can be performed without time restrictions. The Battery -A- can be used constantly.