BATTERY, CHARGING WITH Battery Charger VAS5095A
Risk of injury. Follow all warning messages and safety precautions. Refer to WARNINGS AND SAFETY PRECAUTIONS .
Special tools and workshop equipment required
- Battery Charger VAS5095A
While charging, always set the battery type to 2.4 V/C (Volts/Cell)! This applies to all Batteries -A-.
The Battery -A- temperature must be at least 10 °C.
Do not check or charge a Battery -A- when the visual indicator has >>no color or is bright yellow<<. Jump starting must not be used!
There is a risk of explosion during testing, charging or jump starting.
These Batteries -A- must be replaced.
Procedure
-- Turn off the ignition and all electrical consumers and remove the ignition key.
-- Check the battery type setting on the battery type switch. Refer to Battery Charger VAS5095A DEVICE DESCRIPTION . The battery type switch must be set to 2.4V/C (Volts/Cell).
-- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.
On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.
-- Connect the black charge terminal (-) to the negative terminal of the Battery -A- /negative connector.
-- Switch on the Battery Charger VAS5095A. Refer to Battery Charger VAS5095A DEVICE DESCRIPTION .
Charge current displays. Refer to Figure -2- and -3- light up yellow. The Battery -A- is partially charged (approximately 90 %) when only the yellow LED -3- is on.
If the green LED. Refer to Figure -4- is also on, then the Battery Charger VAS5095A has switched to maintenance charging. The Battery -A- is charged.
-- Switch off the Battery Charger VAS5095A. Refer to Battery Charger VAS5095A DEVICE DESCRIPTION .
-- Remove the charging clamps from the battery terminals.