LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 39 (Heating & Air Conditioning) >> 87 Air conditioning >> A/C refrigerant system, testing >> Identifying malfunctions if specified values are not obtained >> Notes

Identifying malfunctions if specified values are not obtained: Notes

WARNING: This page does not describe the selected car, but rather 17 other vehicles, including the 2009 Audi S4, 2009 Audi A4, 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
  • During cooling output test, observe display in zones "1" and "4". Activation for A/C Compressor Regulator Valve N280 deactivated during cooling output test (drop in control current to below 0.55 A)?
↓ Yes ↓ ↓ No ↓
  • Increase in pressure in refrigerant circuit (display zone "4") during cooling output test?
  • Read measuring value block, display group "002" (compressor shutoff criteria) and eliminate cause of shutoff.
↓ Yes ↓ ↓ No ↓
  • Repeat cooling output test.
↓ Test continued (increase in pressure in refrigerant circuit) Continuation of test - Pressure in refrigerant circuit increases 
  • Fault in refrigerant circuit * See note.

* If applicable, check again that compressor is actually being driven. On vehicles with 8-cyl. engine, the drive shaft may have become removed from the compressor drive unit for example → Compressor drive unit, checking, replacing