LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 33 (Brake System) >> 47 - Brakes - Hydraulic components >> Brake system vacuum pump V192 >> Reading measured value block

Reading measured value block

WARNING: This page does not describe the selected car, but rather 17 other vehicles, including the 2009 Audi S4, 2009 Audi A4, 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.

Indicated on display (function selection): Vehicle system - test HELP Select function XX

Indicated on display: Read measured value block HELP Enter display group number XXX

Display group 008 

Read measured value block 8 → Indicated on display:
Operated/not operated Pump off Pump on XXX mbar Test off/Test on  
      Test
  • Test (short test) off
  • Test (short test) on
    Vacuum
  • Vacuum measured at brake booster unit
  • Display for ventilated brake booster unit approx. 960, for evacuated brake booster unit approx. 450, depending on ambient pressure.
  Vacuum pump
  • Pump off
  • Pump on
  • If pump does not run although display shows "Pump on" conduct fault finding according to current flow diagram.
Brake pedal:
  • Brake pedal not depressed
  • Brake pedal depressed
  • In the event of any deviations check brake light switch.