Performing check measurement
WARNING: This page is about a different car, the 2005 Audi A4, 2004 Audi A4, 2003 Audi A4, and 2002 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
Checking dimension "r"
- Install drive pinion with determined shims "S3" and "S4" and turn 5 turns in both directions.
- Insert universal mandrel "Determining measurement `e'". Refer to Determining dimension "e" , and perform check measurement.
- Read off dial gauge counterclockwise (red scale).
- If the shims have been correctly selected, the deviation "r" (marked on outer circumference of ring gear) must be shown within a tolerance of ± 0.04 mm.