LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 1225 (Hydraulic Components) >> 47 Hydraulic Components >> Brake Booster Vacuum Supply >> Brake Booster Vacuum System, Checking >> Vacuum, Checking

Vacuum, Checking

WARNING: This page is about a different car, the 2014 Volkswagen Touareg, 2013 Volkswagen Touareg, 2012 Volkswagen Touareg, and 2011 Volkswagen Touareg. However, it is still accessible from the selected car via links, so may be relevant.

Special Tools And Workshop Equipment Required 

NOTE:

The average earth atmospheric air pressure at sea level (N. N.) is 1013 mbar (14.7psi) and it decreases dramatically at higher altitudes (approximately 100 mbar (1.4 psi) every 1000 meters higher) Local and time fluctuations will influence the vacuum.

A cold engine, the Air Conditioning (A/C) switched being on and even only the engine idling can negatively influence the vacuum.

-- Check all the vacuum hoses beforehand for damage (for example, tears or damaged caused by animals) and make sure they are secure

-- Connect the Brake Servo Tester:VAS6721  . Refer to Brake Servo Tester .

-- Open the shut-off valve -A-.

-- Close the shut-off valves -B+C-.

Fig 1: Identifying VAS 6721 Shut-Off Valves
GWWN47-10210Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Start the warm (above 60 °C (140 °F)) engine and press the accelerator pedal one time quickly (engine RPM higher than 2, 000).

-- Read the measured value displayed.

Normally (see note) the vacuum should be between 600 and 950 mbar (8.7 and 13.77 psi) (depending on the engine installed).

Check the vacuum system for leaks if the measured value is not reached, even though all requirements (see notes).

-- Create the vacuum using a Hand Vacuum Pump:VAS 6213  for comparison purposes. Refer to VACUUM, CREATING WITH Hand Vacuum Pump .

Opening the shut-off valve -B- makes it easier to remove the hose connections and the adapter.