Engine Control Module --, 2016 My
| DTC / Description | Monitor Strategy Description | Malfunction Criteria and Threshold Value | Secondary Parameters with Enable Conditions | Monitoring Time Length | MIL Illumination | Component Diagnostic Procedure |
|---|---|---|---|---|---|---|
| P00A2 Charge Air Cooler Temperature Sensor Circuit Low Bank 2 | Charge air temperature sensor downstream charge air cooler signal range check low |
|
|
|
|
-- Check the Charge Air Temperature Sensor After Charge Air Cooler -G811- Refer to CHARGE AIR TEMPERATURE SENSOR AFTER CHARGE AIR COOLER -G811-, CHECKING |
| P00A3 Charge Air Cooler Temperature Sensor Circuit High Bank 2 | Charge air temperature sensor downstream charge air cooler signal range check high |
|
|
|
|
-- Check the Charge Air Temperature Sensor After Charge Air Cooler -G811- Refer to CHARGE AIR TEMPERATURE SENSOR AFTER CHARGE AIR COOLER -G811-, CHECKING |
| P0016 Crankshaft Position-Camshaft Position Correlation Bank 1 Sensor A | Phase Sensor for Camshaft Wrong assignment between camshaft and crankshaft signal |
|
|
|
|
-- Check the Camshaft Position Sensor -G40-. Refer to CAMSHAFT POSITION SENSOR -G40-, CHECKING . |
| P0030 O2 Sensor Heater Control Bank 1 Sensor 1 | Oxygen sensor LSU heater (output driver) open circuit |
|
|
|
|
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to OXYGEN SENSOR 1 BEFORE CATALYTIC CONVERTER -GX10-, CHECKING . |
| P0031 O2 Sensor Heater Control Circuit Low Bank 1 Sensor 1 | Oxygen sensor LSU heater (output driver) short to ground |
|
|
|
|
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to OXYGEN SENSOR 1 BEFORE CATALYTIC CONVERTER -GX10-, CHECKING . |
| P0032 O2 Sensor Heater Control Circuit Bank 1 Sensor 1 High | Oxygen sensor LSU heater (output driver) short to battery plus |
|
|
|
|
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to OXYGEN SENSOR 1 BEFORE CATALYTIC CONVERTER -GX10-, CHECKING . |
| P0045 Turbocharger/Supercharger Boost Control Solenoid A Circuit/Open | Turbo charger actuator Open Circuit |
|
|
|
|
-- Check the Wastegate Bypass Regulator Valve -N75-. Refer to WASTEGATE BYPASS REGULATOR VALVE -N75-, CHECKING . |
| P0047 Turbocharger/Supercharger Boost Control Solenoid A Circuit Low | Turbo charger actuator Short to Ground |
|
|
|
|
-- Check the Wastegate Bypass Regulator Valve -N75-. Refer to WASTEGATE BYPASS REGULATOR VALVE -N75-, CHECKING . |
| P0048 Turbocharger/Supercharger Boost Control Solenoid A Circuit High | Turbo charger actuator Short to Battery voltage |
|
|
|
|
-- Check the Wastegate Bypass Regulator Valve -N75-. Refer to WASTEGATE BYPASS REGULATOR VALVE -N75-, CHECKING . |
| P007B Charge Air Cooler Temperature Sensor Circuit Range/Performance Bank 1 | Charge air temperature sensor upstream charge air cooler cross check of temperature sensors at cold start conditions |
|
|
|
|
-- Check the Charge Pressure Actuator Position Sensor -G581- Refer to CHARGE PRESSURE ACTUATOR POSITION SENSOR - G581-, CHECKING |
| P007C Charge Air Cooler Temperature Sensor Circuit Low Bank 1 | Charge air temperature sensor upstream charge air cooler signal range check low |
|
|
|
|
-- Check the Charge Air Temperature Sensor After Charge Air Cooler -G811- Refer to CHARGE AIR TEMPERATURE SENSOR AFTER CHARGE AIR COOLER -G811-, CHECKING |
| P007D Charge Air Cooler Temperature Sensor Circuit High Bank 1 | Charge air temperature sensor upstream charge air cooler signal range check high |
|
|
|
|
-- Check the Charge Air Temperature Sensor After Charge Air Cooler -G811- Refer to CHARGE AIR TEMPERATURE SENSOR AFTER CHARGE AIR COOLER -G811-, CHECKING |
| P0070 Ambient Air Temperature Sensor Circuit | Environmental temperature sensor via CAN /SRC-signal via CAN signal range check high |
|
|
|
|
-- Check the Outside Air Temperature Sensor -G17-. Refer to OUTSIDE AIR TEMPERATURE SENSOR -G17-, CHECKING |
| P0071 Ambient Air Temperature Sensor Circuit Range/Performance | Environmental temperature sensor via CAN /SRC-signal via CAN No plausible error value |
|
|
|
|
-- Check the Outside Air Temperature Sensor -G17-. Refer to OUTSIDE AIR TEMPERATURE SENSOR -G17-, CHECKING |
| Environmental temperature sensor cross check of temperature sensors (engine part) at cold start conditions |
|
|
|
|
-- Check Fuel Temperature Sensor -G81-. Refer to FUEL TEMPERATURE SENSOR -G81-, CHECKING . | |
| P0072 Ambient Air Temperature Sensor Circuit Low | Environmental temperature sensor via CAN /SRC-signal via CAN signal range check low |
|
|
|
|
-- Check the Outside Air Temperature Sensor -G17-. Refer to OUTSIDE AIR TEMPERATURE SENSOR -G17-, CHECKING |
| P0087 Fuel Rail/System Pressure - Too Low | Rail Pressure Control monitoring of absolute rail-pressure and rail-pressure deviation |
|
|
|
|
-- Check the Fuel Metering Valve -N290-. Refer to FUEL METERING VALVE -N290-, CHECKING . -- Check the Fuel Pressure Regulator Valve -N276-. Refer to FUEL PRESSURE REGULATOR VALVE - N276-, CHECKING . -- Check the Fuel Pressure Sensor -G247-. Refer to FUEL PRESSURE SENSOR - G247-, CHECKING . |
|
|
|||||
| P0088 Fuel Rail Pressure Control Too High | Rail Pressure Control monitoring of absolute rail-pressure and rail-pressure deviation |
|
|
|
|
-- Check the Fuel Metering Valve -N290-. Refer to FUEL METERING VALVE -N290-, CHECKING . -- Check the Fuel Pressure Regulator Valve -N276-. Refer to FUEL PRESSURE REGULATOR VALVE - N276-, CHECKING . -- Check the Fuel Pressure Sensor -G247-. Refer to FUEL PRESSURE SENSOR - G247-, CHECKING . |
|
|
|
||||
| P0090 Fuel Pressure Regulator 1 Control Circuit/Open | Metering unit / fuel volume regulator open circuit |
|
|
|
|
-- Check the Fuel Pressure Regulator Valve -N276-. Refer to FUEL PRESSURE REGULATOR VALVE - N276-, CHECKING . |
| P0091 Fuel Pressure Regulator 1 Control Circuit Low | Metering unit / fuel volume regulator Short to Ground |
|
|
|
|
-- Check the Fuel Pressure Regulator Valve -N276-. Refer to FUEL PRESSURE REGULATOR VALVE - N276-, CHECKING . |
| P0092 Fuel Pressure Regulator 1 Control Circuit High | Metering unit / fuel volume regulator Short to Battery Voltage |
|
|
|
|
-- Check the Fuel Pressure Regulator Valve -N276-. Refer to FUEL PRESSURE REGULATOR VALVE - N276-, CHECKING . |
| P00A1 Charge Air Cooler Temperature Sensor Circuit Range/Performance Bank 2 | Charge air temperature sensor downstream charge air cooler cross check of temperature sensors at cold start conditions |
|
|
|
|
-- Check the Charge Air Temperature Sensor After Charge Air Cooler -G811- Refer to CHARGE AIR TEMPERATURE SENSOR AFTER CHARGE AIR COOLER -G811-, CHECKING |
| P00AF Turbocharger/Supercharger Boost Control A Module Performance | Turbo charger actuator position control loop Comparison of actual and desired position signal |
|
|
|
|
-- Check the Charge Pressure Actuator Position Sensor -G581-. Refer to CHARGE PRESSURE ACTUATOR POSITION SENSOR - G581-, CHECKING . -- Check the Wastegate Bypass Regulator Valve -N75-. Refer to WASTEGATE BYPASS REGULATOR VALVE -N75-, CHECKING . |
|
|
|
||||
| P00BC Mass or Volume Air Flow "A" Circuit Range/Performance - Air Flow Too Low | Mass Air Flow Sensor Adaptation |
|
|
|
-- Check the Mass Air Flow (MAF) Sensor -G70-. Refer to MASS AIRFLOW SENSOR -G70-, CHECKING . | |
| P00BD Mass or Volume Air Flow "A" Circuit Range/Performance - Air Flow Too High | Mass Air Flow Sensor Adaptation |
|
|
|
|
-- Check the Mass Air Flow (MAF) Sensor -G70-. Refer to MASS AIRFLOW SENSOR -G70-, CHECKING . |
| P00C6 Fuel Rail Pressure Too Low - Engine Cranking Bank 1 | Monitoring of Rail Pressure during Engine Start (Cranking) |
|
|
|
|
-- Check the Fuel Metering Valve -N290-. Refer to FUEL METERING VALVE -N290-, CHECKING . -- Check the Fuel Pressure Regulator Valve -N276-. Refer to FUEL PRESSURE REGULATOR VALVE - N276-, CHECKING . -- Check the Fuel Pressure Sensor -G247-. Refer to FUEL PRESSURE SENSOR - G247-, CHECKING . |
| P0101 "Mass or Volume Air Flow Circuit Range/Performance" | Mass Air Flow Circuit Plausibility check | Plausibility check by model air mass min.
|
|
|
|
-- Check the Mass Air Flow (MAF) Sensor -G70-. Refer to MASS AIRFLOW SENSOR -G70-, CHECKING . |
Plausibility check by model air mass max.
|
|
|||||
| Mass Air Flow Circuit Range Check High Temp. Calculated Value |
|
|
|
|||
| Mass Air Flow Circuit Range Check Low Temp. Calculated Value |
|
|
||||
| P0102 Mass or Volume Air Flow Circuit Low Input | Mass Air Flow Circuit signal range check low raw value | Range check low Raw value:
|
|
|
|
-- Check the Mass Air Flow (MAF) Sensor -G70-. Refer to MASS AIRFLOW SENSOR -G70-, CHECKING . |
| P0103 Mass or Volume Air Flow Circuit High Input | Mass Air Flow Circuit signal range check high raw value | Range check High Raw value:
|
|
|
|
-- Check the Mass Air Flow (MAF) Sensor -G70-. Refer to MASS AIRFLOW SENSOR -G70-, CHECKING . |
| P0104 Mass or Volume Air Flow Circuit Intermittent | Mass Air Flow Open Circuit |
|
|
|
|
-- Check the Mass Air Flow (MAF) Sensor -G70-. Refer to MASS AIRFLOW SENSOR -G70-, CHECKING . |
| P0111 Intake Air Temperature Sensor 1 Bank 1 Circuit Range/Performance | Intake air temperature at airflow sensor plausibility with ambient temperature sensor after engine cold start |
|
|
|
|
-- Check Charge Air Temperature Sensor In Front Of Charge Air Cooler -G810-. Refer to CHARGE AIR TEMPERATURE SENSOR IN FRONT OF CHARGE AIR COOLER -G810-, CHECKING . |
|
||||||
| P0116 Engine Coolant Temperature Sensor 1 Circuit Range/Performance | Coolant temperature sensor engine downstream warm up time plausibility |
|
|
|
|
-- Check the Engine Coolant Temperature Sensor -G62-. Refer to ENGINE COOLANT TEMPERATURE SENSOR -G62-, CHECKING . |
| Coolant temperature sensor engine downstream cross check of temperature sensors at cold start conditions |
|
|
|
|
||
| P0117 Engine Coolant Temperature Sensor 1 Circuit Low | Coolant temperature sensor engine downstream signal range check low |
|
|
|
-- Check the Engine Coolant Temperature Sensor -G62-. Refer to ENGINE COOLANT TEMPERATURE SENSOR -G62-, CHECKING . | |
| P0118 Engine Coolant Temperature Sensor 1 Circuit High | Coolant temperature sensor engine downstream signal range check high |
|
|
|
-- Check the Engine Coolant Temperature Sensor -G62-. Refer to ENGINE COOLANT TEMPERATURE SENSOR -G62-, CHECKING . | |
| P0121 Throttle / Pedal Position Sensor A Circuit Range/Performance | Throttle valve actuator position sensor signal in desired range during closed position learning |
|
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING
. -- Check for any TSB's that may apply to this fault. If multiple codes are set, perform diagnosis for any fuel system, engine speed sensor, MAF or MAP related faults first. |
| Throttle valve actuator Physical signal range check high /low |
|
|
|
|||
| P0122 Throttle / Pedal Position Sensor A Circuit Low Input | Throttle valve position sensor signal range check low |
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING
. -- Check for any TSB's that may apply to this fault. If multiple codes are set, perform diagnosis for any fuel system, engine speed sensor, MAF or MAP related faults first. |
|
| P0123 Throttle / Pedal Position Sensor A Circuit High Input | Throttle valve position sensor signal range check high |
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING
. -- Check for any TSB's that may apply to this fault. If multiple codes are set, perform diagnosis for any fuel system, engine speed sensor, MAF or MAP related faults first. |
|
| P0128 Coolant Thermostat Coolant Temperature Below Thermostat Regulating Temperature | Thermostat plausibility check |
|
|
|
|
-- Check the the rmostat for proper operation. Refer to the Repair information for Diagnostic. -- Check the Engine Coolant Temperature Sensor -G62-. Refer to ENGINE COOLANT TEMPERATURE SENSOR -G62-, CHECKING . -- Check the Engine Coolant Temperature Sensor On Radiator Outlet -G83-. Refer to ENGINE COOLANT TEMPERATURE SENSOR ON RADIATOR OUTLET -G83-, CHECKING . |
| P0131 O2 Sensor Circuit Bank 1 Sensor 1 Low Voltage | Oxygen sensor LSU short to ground |
|
|
|
|
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to OXYGEN SENSOR 1 BEFORE CATALYTIC CONVERTER -GX10-, CHECKING . |
| P0132 O2 Sensor Circuit Bank 1 Sensor 1 High Voltage | Oxygen sensor LSU short to battery plus |
|
|
|
|
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to OXYGEN SENSOR 1 BEFORE CATALYTIC CONVERTER -GX10-, CHECKING . |
| P0133 O2 Sensor Circuit Bank 1 Sensor 1 Slow Response | Oxygen sensor LSU dynamic check (comparison of signal energy of high pass filtered lambda signals) |
|
|
|
|
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to OXYGEN SENSOR 1 BEFORE CATALYTIC CONVERTER -GX10-, CHECKING . |
| P0135 O2 Sensor Heater Circuit Bank 1 Sensor 1 Malfunction" | Oxygen sensor LSU heater (control) rationality check |
|
|
|
|
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to OXYGEN SENSOR 1 BEFORE CATALYTIC CONVERTER -GX10-, CHECKING . |
| P0181 Fuel Temperature Sensor A Circuit Range/Performance | Fuel Temperature Sensor cross check of temperature sensors (engine part) at cold start conditions |
|
|
|
|
-- Check Fuel Temperature Sensor -G81-. Refer to FUEL TEMPERATURE SENSOR -G81-, CHECKING . |
| P0182 Fuel Temperature Sensor A Circuit Low Input | Fuel Temperature Sensor signal range check low |
|
|
|
-- Check Fuel Temperature Sensor -G81-. Refer to FUEL TEMPERATURE SENSOR -G81-, CHECKING . | |
| P0183 Fuel Temperature Sensor A Circuit High Input | Fuel Temperature Sensor signal range check high |
|
|
|
-- Check Fuel Temperature Sensor -G81-. Refer to FUEL TEMPERATURE SENSOR -G81-, CHECKING . | |
| P190B Coolant pump for charge air cooling Temperature shutdown | Water pump for charge air intercooler coolant pump overheated |
|
|
|
|
-- Check the Charge Air Cooling Pump -V188-. Refer to CHARGE AIR COOLING PUMP -V188-, CHECKING |
| P190D Coolant pump for charge air cooling Mechanical failure | Water pump for charge air intercooler coolant pump blocked |
|
|
|
-- Check the Charge Air Cooling Pump -V188-. Refer to CHARGE AIR COOLING PUMP -V188-, CHECKING | |
| Water pump for charge air intercooler min speed not reached |
|
|||||
| P190E Coolant pump for charge air cooling Supply voltage | Water pump for charge air intercooler missing live signal |
|
|
|
-- Check the Charge Air Cooling Pump -V188-. Refer to CHARGE AIR COOLING PUMP -V188-, CHECKING | |
| P0191 Fuel Rail Pressure Sensor Circuit Range/Performance Bank 1 | Fuel rail pressure sensor Offset detection during ECU keep alive time |
|
|
|
|
-- Check the Fuel Pressure Sensor -G247-. Refer to FUEL PRESSURE SENSOR - G247-, CHECKING . |
| Fuel rail pressure sensor adaptation of pressure control valve (PCV) characteristic curve by comparison of fuel pressure sensor value and calc. value by PCV duty cycle |
|
|
||||
| P0192 Fuel Rail Pressure Sensor Circuit Low Bank 1 | Fuel rail pressure sensor signal range check high/low |
|
|
|
-- Check the Fuel Pressure Sensor -G247-. Refer to FUEL PRESSURE SENSOR - G247-, CHECKING . | |
| P0193 Fuel Rail Pressure Sensor Circuit High Bank 1 | Fuel rail pressure sensor signal range check high/low |
|
|
|
-- Check Fuel Pressure Sensor -G247-. Refer to FUEL PRESSURE SENSOR - G247-, CHECKING . | |
| P0201 Cylinder 1 Injector "A" Circuit | Cylinder 1 Injector Circuit Open / short circuit |
|
|
|
|
-- Check the Cylinder 1 Fuel Injector -N30-. Refer to FUEL INJECTOR --, CHECKING . |
| P0202 Cylinder 2 Injector "A" Circuit | Cylinder 2 Injector Circuit Open / short circuit |
|
|
|
|
-- Check the Cylinder 2 Fuel Injector -N31-. Refer to FUEL INJECTOR --, CHECKING . |
| P0203 Cylinder 3 Injector "A" Circuit | Cylinder 3 Injector Circuit Open / short circuit |
|
|
|
|
-- Check the Cylinder 3 Fuel Injector -N32-. Refer to FUEL INJECTOR --, CHECKING . |
| P0204 Cylinder 4 Injector "A" Circuit | Cylinder 4 Injector Circuit Open / short circuit |
|
|
|
|
-- Check the Cylinder 4 Fuel Injector -N33-. Refer to FUEL INJECTOR --, CHECKING . |
| P020A Cylinder 1 Injection Timing | Position control loop main combustion comparison of actual and desired position main combustion (positive and negative control error) cylinder #1 |
|
|
|
|
-- Check Camshaft Position Sensor -G40- Refer to CAMSHAFT POSITION SENSOR -G40-, CHECKING -- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING .-- Check Fuel Injectors -N30, N31, N32, N33-. Refer to FUEL INJECTOR --, CHECKING . |
| P020B Cylinder 2 Injection Timing | Position control loop main combustion comparison of actual and desired position main combustion (positive and negative control error) cylinder #2 |
|
|
|
|
-- Check Camshaft Position Sensor -G40- Refer to CAMSHAFT POSITION SENSOR -G40-, CHECKING -- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING .-- Check Fuel Injectors -N30, N31, N32, N33-. Refer to FUEL INJECTOR --, CHECKING . |
| P020C Cylinder 3 Injection Timing | Position control loop main combustion comparison of actual and desired position main combustion (positive and negative control error) cylinder #3 |
|
|
|
|
-- Check Camshaft Position Sensor -G40- Refer to CAMSHAFT POSITION SENSOR -G40-, CHECKING -- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING .-- Check Fuel Injectors -N30, N31, N32, N33-. Refer to FUEL INJECTOR --, CHECKING . |
| P020D Cylinder 4 Injection Timing | Position control loop main combustion comparison of actual and desired position main combustion (positive and negative control error) cylinder #4 |
|
|
|
|
-- Check Camshaft Position Sensor -G40- Refer to CAMSHAFT POSITION SENSOR -G40-, CHECKING -- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING .-- Check Fuel Injectors -N30, N31, N32, N33-. Refer to FUEL INJECTOR --, CHECKING . |
| P0230 Fuel Pump Primary Circuit | Electric Fuel Pump Short Circuit |
|
|
|
-- Check the Fuel Delivery Unit -GX1- Refer to FUEL PUMP CONTROL MODULE - J538- / FUEL DELIVERY UNIT -GX1-, CHECKING | |
| Electric Fuel Pump electric fault circuit |
|
|||||
| P0234 Turbo/Super Charger Overboost Condition | Boost pressure control loop comparison of actual and desired boost-pressure |
|
|
|
|
-- Check Charge Air Pressure Sensor -G31-. Refer to CHARGE AIR PRESSURE SENSOR - G31-, CHECKING . |
| P0236 Turbocharger Boost Sensor (A) Circuit Range/Performance | Boost pressure sensor plausibility with barometric pressure sensor before engine start |
|
|
|
|
-- Check Charge Air Pressure Sensor -G31-. Refer to CHARGE AIR PRESSURE SENSOR - G31-, CHECKING . |
| P0237 Turbocharger Boost Sensor (A) Circuit Low Input | Boost pressure sensor signal range check |
|
|
|
|
-- Check Charge Air Pressure Sensor -G31-. Refer to CHARGE AIR PRESSURE SENSOR - G31-, CHECKING . |
| P0238 Turbocharger Boost Sensor (A) Circuit High Input | Boost pressure sensor signal range check |
|
|
|
|
-- Check Charge Air Pressure Sensor -G31-. Refer to CHARGE AIR PRESSURE SENSOR - G31-, CHECKING . |
| P023A Charge Air Cooler Coolant Pump Control Circuit/Open | Water pump for charge air intercooler open circuit |
|
|
|
|
-- Check the Charge Air Cooling Pump -V188-. Refer to CHARGE AIR COOLING PUMP -V188-, CHECKING |
| P023B Charge Air Cooler Coolant Pump Control Circuit Low | Water pump for charge air intercooler short to ground |
|
|
|
|
-- Check the Charge Air Cooling Pump -V188-. Refer to CHARGE AIR COOLING PUMP -V188-, CHECKING |
| P023C Charge Air Cooler Coolant Pump Control Circuit High | Water pump for charge air intercooler short to battery plus |
|
|
|
|
-- Check the Charge Air Cooling Pump -V188-. Refer to CHARGE AIR COOLING PUMP -V188-, CHECKING |
| P025A Fuel Pump Module Control Circuit/Open | Electric fuel pump output driver open circuit |
|
|
|
|
-- Check the Fuel Delivery Unit -GX1- Refer to FUEL PUMP CONTROL MODULE - J538- / FUEL DELIVERY UNIT -GX1-, CHECKING |
| P025C Fuel Pump Module Control Circuit Low | Electric fuel pump output driver short to ground |
|
|
|
|
-- Check the Fuel Delivery Unit -GX1- Refer to FUEL PUMP CONTROL MODULE - J538- / FUEL DELIVERY UNIT -GX1-, CHECKING |
| P025D Fuel Pump Module Control Circuit High | Electric fuel pump output driver short to battery plus |
|
|
|
|
-- Check the Fuel Delivery Unit -GX1- Refer to FUEL PUMP CONTROL MODULE - J538- / FUEL DELIVERY UNIT -GX1-, CHECKING |
| P0263 Cylinder 1 Contribution/Balance | Cylinder 1 monitoring of zero fuel calibration values |
|
Enable Conditions For Adaptation:
|
|
|
-- Check the Glow Plug 1 -QX1-. Refer to GLOW PLUG 1 -QX1-, CHECKING . -- Check the Cylinder 1 Fuel Injector -N30-. Refer to FUEL INJECTOR --, CHECKING . |
| Learning point at valve closing time adaptation limits |
|
|
|
|||
| P0266 Cylinder 2 Contribution/Balance | Cylinder 2 monitoring of fuel calibration values |
|
Enable conditions for adaptation:
|
|
|
-- Check the Glow Plug 2 -QX2-. Refer to GLOW PLUG 2 -QX2-, CHECKING . -- Check the Cylinder 2 Fuel Injector -N31-. Refer to FUEL INJECTOR --, CHECKING . |
| Learning point at valve closing time adaptation limits |
|
|
|
|||
| P0269 Cylinder 3 Contribution/Balance | Cylinder 3 monitoring of fuel calibration values |
|
Enable conditions for adaptation:
|
|
|
-- Check the Glow Plug 3 -QX3-. Refer to GLOW PLUG 3 -QX3-, CHECKING . -- Check the Cylinder 3 Fuel Injector -N32-. Refer to FUEL INJECTOR --, CHECKING . |
| Learning point at valve closing time adaptation limits |
|
|
|
|||
| P026A Charge Air Cooler Efficiency Below Threshold | Charge air intercooler monitoring of temperature difference (control error) between set point and measured value |
|
|
|
|
-- Check the air to air intercooler in front of the radiator for debris obstructing the cooling fins, restricted or collapsed hoses, damaged or missing lower fascia or splash shield. Correct the condition and clear the DTC. Test drive vehicle. -- Check the Charge Air Pressure Sensor -G31-. Refer to CHARGE AIR PRESSURE SENSOR - G31-, CHECKING . |
| P0272 Cylinder 4 Contribution/Balance | Cylinder 4 monitoring of fuel calibration values |
|
Enable conditions for adaptation:
|
|
|
-- Check the Glow Plug 4 -QX4-. Refer to GLOW PLUG 4 -QX4-, CHECKING . -- Check the Cylinder 4 Fuel Injector -N33-. Refer to FUEL INJECTOR --, CHECKING . |
| Learning point at valve closing time adaptation limits |
|
|
|
|||
| P0299 Turbo/Super Charger Underboost | Charge Air Boost Pressure Rationality Check High |
|
|
|
|
-- Check the Charge Air Pressure Sensor -G31-. Refer to CHARGE AIR PRESSURE SENSOR - G31-, CHECKING . |
| P0300 Random/Multiple Cylinder Misfire Detected | Misfire Detection Instantaneous Engine Speed Monitoring |
|
|
|
|
-- Check the Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING . -- Check the Camshaft Position Sensor -G40-. Refer to CAMSHAFT POSITION SENSOR -G40-, CHECKING . -- Check Fuel Injectors --. Refer to FUEL INJECTOR --, CHECKING . |
| Misfire detection cylinder pressure sensor based calculated inner torque fall below threshold under positive torque engine speeds |
|
|
|
|||
| P0301 Cylinder 1 Misfire Detected | Misfire Detection Instantaneous Engine Speed Monitoring |
|
|
|
|
-- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING .-- Check Fuel Injectors --. Refer to FUEL INJECTOR --, CHECKING . |
| Misfire detection cylinder pressure sensor based calculated inner torque fall below threshold under positive torque engine speeds |
|
|
|
|||
| P0302 Cylinder 2 Misfire Detected | Misfire Detection Instantaneous Engine Speed Monitoring |
|
|
|
|
-- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING .-- Check Fuel Injectors --. Refer to FUEL INJECTOR --, CHECKING . |
| Misfire detection cylinder pressure sensor based calculated inner torque fall below threshold under positive torque engine speeds |
|
|
|
|||
| P0303 Cylinder 3 Misfire Detected | Misfire Detection Instantaneous Engine Speed Monitoring |
|
|
|
|
-- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING .-- Check Fuel Injectors --. Refer to FUEL INJECTOR --, CHECKING . |
| Misfire detection cylinder pressure sensor based calculated inner torque fall below threshold under positive torque engine speeds |
|
|
|
|||
| P0304 Cylinder 4 Misfire Detected | Misfire Detection Instantaneous Engine Speed Monitoring |
|
|
|
|
-- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING .-- Check Fuel Injectors --. Refer to FUEL INJECTOR --, CHECKING . |
| Misfire detection cylinder pressure sensor based calculated inner torque fall below threshold under positive torque engine speeds |
|
|
|
|||
| P0321 Ignition / Distributor Engine Speed Input Circuit Range/Performance | Crank angle / engine speed sensor plausibility of crankshaft signal |
|
|
|
|
-- Check the Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING . |
| P0322 Ignition / Distributor Engine Speed Input Circuit No Signal | Crank angle / engine speed sensor plausibility (no increment signal) |
|
|
|
|
-- Check the Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING . |
| P0341 Camshaft Position Sensor Circuit Range/Performance | Phase sensor for camshaft Signal Not Plausible |
|
|
|
|
-- Check the Camshaft Position Sensor -G40- Refer to CAMSHAFT POSITION SENSOR -G40-, CHECKING |
| P0381 Glow Plug/Heater Indicator Circuit | Glow Plug Control Indicator Lamp error message from instrument panel |
|
|
|
|
-- Check the CAN Bus. Refer to appropriate repair information. |
| P0383 Glow Plug Control Module Control Circuit Low | Glow Plug Time Control Module Control Circuit Short to Ground |
|
|
|
|
-- Check the Automatic Glow Time Control Module -J179-. Refer to.AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P0401 Exhaust Gas Recirculation Flow Insufficient Detected | EGR control loop EGR mass flow monitoring |
|
|
|
|
-- Check the EGR Valve 1 -GX5-. Refer to EGR VALVE 1 - GX5 -, CHECKING . -- Check the EGR Valve 2 -GX6-. Refer to EGR VALVE 2 -GX6-, CHECKING . |
| P0402 Exhaust Gas Recirculation Flow Excessive Detected | EGR control loop EGR mass flow monitoring |
|
|
|
|
-- Check the EGR Valve 1 -GX5-. Refer to EGR VALVE 1 - GX5 -, CHECKING . -- Check the EGR Valve 2 -GX6-. Refer to EGR VALVE 2 -GX6-, CHECKING . |
| P0403 Exhaust Gas Recirculation Circuit | HP EGR Actuator Circuit Open load |
|
|
|
|
-- Check the EGR Valve 1 -GX5-. Refer to EGR VALVE 1 - GX5 -, CHECKING . |
| HP EGR Actuator Circuit Short to Ground or Malfunction Error |
|
|
|
|||
| HP EGR Actuator Circuit Short to Battery Voltage | ||||||
| HP EGR Actuator Circuit Functional check: Stuck Close |
|
|||||
| HP EGR Actuator Circuit Functional check: Stuck Open |
|
|||||
| Comparison of actual and desired position signal |
|
|
||||
| P0405 Exhaust Gas Recirculation Sensor A Circuit Low | HP EGR Position Sensor signal range check low |
|
|
|
-- Check the EGR Valve 1 -GX5-. Refer to EGR VALVE 1 - GX5 -, CHECKING . | |
| P0406 Exhaust Gas Recirculation Sensor A Circuit High | HP EGR Position Sensor signal range check high |
|
|
|
|
-- Check the EGR Valve 1 -GX5-. Refer to EGR VALVE 1 - GX5 -, CHECKING . |
| P040C Exhaust Gas Recirculation Temperature Sensor "A" Circuit Low | Exhaust gas temperature sensor downstream LP EGR cooler signal range check low |
|
|
|
|
-- Check Exhaust Gas Temperature Sensor 1 -G235-. Refer to EXHAUST GAS TEMPERATURE SENSOR 1 -G235-, CHECKING . |
| P040D Exhaust Gas Recirculation Temperature Sensor "A" Circuit High | Exhaust gas temperature sensor downstream LP EGR cooler signal range check high |
|
|
|
|
-- Check Exhaust Gas Temperature Sensor 1 -G235-. Refer to EXHAUST GAS TEMPERATURE SENSOR 1 -G235-, CHECKING . |
| P041B EGR Temperature Sensor "B" Circuit Range/Performance | Exhaust gas temperature sensor downstream LP EGR cooler comparison of exhaust gas temperature sensor downstream low-pressure EGR with model value |
|
|
|
|
-- Check Exhaust Gas Temperature Sensor 1 -G235-. Refer to EXHAUST GAS TEMPERATURE SENSOR 1 -G235-, CHECKING . |
| Exhaust gas temperature sensor downstream LP EGR cooler cross check of temperature sensors (exhaust part) at cold start conditions |
|
|
|
|||
| P0420 Catalyst System Bank 1 Efficiency Below Threshold | Non-Methane Hydrocarbon (NMHC) Catalyst comparison of current heat quantity input and modeled heat quantity input caused by HC conversion |
|
|
|
|
-- Check Exhaust Gas Temperature Sensor 1 -G235-. Refer to EXHAUST GAS TEMPERATURE SENSOR 1 -G235-, CHECKING . |
| NMHC oxidation catalyst monitoring (Conversion Efficiency Emission Threshold) evaluation of the time derivative of the measured temperature downstream oxidation catalyst and the produced heat quantity inside oxidation catalyst caused by intrusive late post injection |
|
|
|
|
||
| P045A Exhaust Gas Recirculation "B" Control Circuit | LP EGR valve actuator open load |
|
|
|
|
-- Check the EGR Valve 2 -GX6-. Refer to EGR VALVE 2 -GX6-, CHECKING . |
| LP EGR valve actuator short circuit over load |
|
|
|
|||
| P045B Exhaust Gas Recirculation "B" Control Circuit Range/Performance | LP EGR valve actuator position sensor signal in desired range during closed position learning |
|
|
|
|
-- Check the EGR Valve 2 -GX6-. Refer to EGR VALVE 2 -GX6-, CHECKING . |
| LP EGR valve actuator Physical signal range check high / low |
|
|
|
|||
| P045C Exhaust Gas Recirculation "B" Control Circuit Low | LP EGR valve actuator short circuit to ground on Out1 / short circuit to ground on Out2 |
|
|
|
|
-- Check the EGR Valve 2 -GX6-. Refer to EGR VALVE 2 -GX6-, CHECKING . |
| P045D Exhaust Gas Recirculation "B" Control Circuit High | LP EGR valve actuator short circuit to battery on Out1 / short circuit to battery on Out2 |
|
|
|
|
-- Check the EGR Valve 2 -GX6-. Refer to EGR VALVE 2 -GX6-, CHECKING . |
| P045E Exhaust Gas Recirculation "B" Control Stuck Open | LP EGR valve position control loop Comparison of actual and desired position signal |
|
|
|
-- Check the EGR Valve 2 -GX6-. Refer to EGR VALVE 2 -GX6-, CHECKING . | |
| P045F Exhaust Gas Recirculation "B" Control Stuck Closed | LP EGR valve position control loop Comparison of actual and desired position signal |
|
|
|
|
-- Check the EGR Valve 2 -GX6-. Refer to EGR VALVE 2 -GX6-, CHECKING . |
| P046C Exhaust Gas Recirculation Sensor "A" Circuit Range/Performance | HP EGR Actuator Position Sensor signal in desired range during closed position learning |
|
|
|
|
-- Check the EGR Valve 1 -GX5-. Refer to EGR VALVE 1 - GX5 -, CHECKING . |
| Physical signal range check high/ low |
|
|
|
|||
| P0470 Exhaust Pressure Sensor "A" | Relative pressure sensor downstream particulate matter trap signal range check high |
|
|
|
-- Check the Differential Pressure Sensor -G505-. Refer to DIFFERENTIAL PRESSURE SENSOR - G505-, CHECKING . | |
| P0471 Exhaust Pressure Sensor "A" Range/Performance | Relative pressure sensor downstream particulate matter trap Offset detection during after run |
|
|
|
|
-- Check the Differential Pressure Sensor -G505-. Refer to DIFFERENTIAL PRESSURE SENSOR - G505-, CHECKING . |
|
||||||
| P0472 Exhaust Pressure Sensor "A" Low | Relative pressure sensor downstream particulate matter trap signal range check low |
|
|
|
-- Check the Differential Pressure Sensor -G505-. Refer to DIFFERENTIAL PRESSURE SENSOR - G505-, CHECKING . | |
| P0474 Exhaust Pressure Sensor "A" Circuit Intermittent/Erratic | Relative pressure sensor downstream particulate matter trap dynamic plausibility of the pressure sensor signal |
|
|
|
|
-- Check the Differential Pressure Sensor -G505-. Refer to DIFFERENTIAL PRESSURE SENSOR - G505-, CHECKING / -- Check the Exhaust Pressure Sensor 1 -G450-. Refer to EXHAUST PRESSURE SENSOR 1 -G450-, CHECKING . |
| P0475 Exhaust Pressure Control Valve "A" | Exhaust flap actuator open load |
|
|
|
|
-- Check Exhaust Door Control Unit -J883-. Refer to EXHAUST DOOR CONTROL UNIT -J883-, CHECKING . |
| Exhaust flap actuator short circuit over load |
|
|
|
|||
| P0477 Exhaust Pressure Control Valve "A" Low | Exhaust flap actuator Short to Ground |
|
|
|
|
-- Check Exhaust Door Control Unit -J883-. Refer to EXHAUST DOOR CONTROL UNIT -J883-, CHECKING . |
| P0478 Exhaust Pressure Control Valve "A" High | Exhaust flap actuator Short to Battery Voltage |
|
|
|
|
-- Check Exhaust Door Control Unit -J883-. Refer to EXHAUST DOOR CONTROL UNIT -J883-, CHECKING . |
| P047F Exhaust Pressure Control Valve "A" Stuck Open | Exhaust flap position control loop comparison of actual and desired position signal |
|
|
|
-- Check Exhaust Door Control Unit -J883-. Refer to EXHAUST DOOR CONTROL UNIT -J883-, CHECKING . | |
| P0486 Exhaust Gas Recirculation Sensor "B" Circuit | LP EGR Position Sensor signal range check low |
|
|
|
-- Check the EGR Valve 2 -GX6-. Refer to EGR VALVE 2 -GX6-, CHECKING . | |
| LP EGR Position Sensor signal range check high |
|
|||||
| P048A Exhaust Pressure Control Valve "A" Stuck Closed | Exhaust flap position control loop comparison of actual and desired position signal |
|
|
|
|
-- Check Exhaust Door Control Unit -J883-. Refer to EXHAUST DOOR CONTROL UNIT -J883-, CHECKING . |
| P048B Exhaust Pressure Control Valve Position Sensor/Switch Circuit | Exhaust Flap Position Sensor signal range check low |
|
|
|
-- Check Exhaust Flap Control Module -J883-. Refer to EXHAUST DOOR CONTROL UNIT -J883-, CHECKING . | |
| P048C Exhaust Pressure Control Valve Position. Sensor / Switch Circuit Range/Performance | Exhaust flap actuator Position Sensor signal in desired range during closed position learning |
|
|
|
|
-- Check Exhaust Door Control Unit -J883-. Refer to EXHAUST DOOR CONTROL UNIT -J883-, CHECKING . |
| Exhaust flap actuator Physical signal range check high / low |
|
|
|
|||
| P048E Exhaust Pressure Control Valve Position. Sensor / Switch Circuit High | Exhaust Flap Position Sensor signal range check high |
|
|
|
-- Check the Exhaust Flap Control Module -J883-. Refer to EXHAUST DOOR CONTROL UNIT -J883-, CHECKING . | |
| P05A0 Active Grille Air Shutter "A" Stuck On | Active Grill Shutter functional check |
|
|
|
-- Check the Radiator Shutter Motor -V544-. Refer to RADIATOR SHUTTER MOTOR -V544-, CHECKING . | |
| P05A2 Active Grille Air Shutter "A" Control Circuit/Open | Active Grill Shutter open circuit |
|
|
|
-- Check the Radiator Shutter Motor -V544-. Refer to RADIATOR SHUTTER MOTOR -V544-, CHECKING . | |
| P05A3 Active Grille Air Shutter "A" Control Circuit Range/Performance | Active Grill Shutter functional check / activity check |
|
|
|
-- Check the Radiator Shutter Motor -V544-. Refer to RADIATOR SHUTTER MOTOR -V544-, CHECKING . | |
|
|
|||||
|
|
|||||
| P05A4 Active Grille Air Shutter "A" Control Circuit High | Active Grill Shutter short to battery plus |
|
|
|
-- Check the Radiator Shutter Motor -V544-. Refer to RADIATOR SHUTTER MOTOR -V544-, CHECKING . | |
| P05A5 Active Grille Air Shutter "A" Control Circuit Low | Active Grill Shutter short to ground |
|
|
|
-- Check the Radiator Shutter Motor -V544-. Refer to RADIATOR SHUTTER MOTOR -V544-, CHECKING . | |
| P05C0 Active Grille Air Shutter Module "A" Over Temperature | Active Grill Shutter functional check |
|
|
|
-- Check the Radiator Shutter Motor -V544-. Refer to RADIATOR SHUTTER MOTOR -V544-, CHECKING . | |
| P0501 Vehicle Speed Sensor "A" Range/Performance | Vehicle speed signal not plausible |
|
|
-- Check the speed signal input. | ||
| P0502 Vehicle Speed Sensor "A" Circuit Low Input | Vehicle Speed Sensor Circuit Low Input |
|
-- Check the speed signal input. | |||
| P0506 Idle Control System RPM Lower than Expected | Idle fuel control system comparison of actual and desired idle speed |
|
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING
. -- Check for any TSB's that may apply to this fault. If multiple codes are set, perform diagnosis for any fuel system, engine speed sensor, MAF or MAP related faults first. |
| P0507 Idle Control System RPM Higher than Expected | Idle fuel control system comparison of actual and desired idle speed |
|
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING
. -- Check for any TSB's that may apply to this fault. If multiple codes are set, perform diagnosis for any fuel system, engine speed sensor, MAF or MAP related faults first. |
| P050E Cold Start Engine Exhaust Temperature Too Low | Exhaust gas temperature sensor downstream oxicat comparison of exhaust gas temperature sensor oxicat downstream with model value |
|
|
|
|
-- Check Exhaust Gas Temperature Sensors --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1 -G235-, CHECKING /EXHAUST GAS TEMPERATURE SENSOR 2 -G448-, CHECKING /EXHAUST GAS TEMPERATURE SENSOR 3 -G495-, CHECKING /EXHAUST GAS TEMPERATURE SENSOR 4 -G648-, CHECKING -- Check the Exhaust Flap Control Module -J883-. Refer to EXHAUST DOOR CONTROL UNIT -J883-, CHECKING . |
| Exhaust temperature control loop (temperature upstream turbine) during CSERS TTCL of temperature upstream turbine |
|
|
|
|
||
| P0544 Exhaust Gas Temperature Sensor Circuit - Bank 1 | Exhaust Gas Temperature Sensor Upstream Turbocharger signal range check high |
|
|
|
-- Check the Exhaust Gas Temperature Sensor 1 -G235-. Refer to EXHAUST GAS TEMPERATURE SENSOR 1 -G235-, CHECKING . | |
| P0545 Exhaust Gas Temperature Sensor Circuit - Bank 1 Low | Exhaust Gas Temperature Sensor Upstream Turbocharger signal range check low |
|
|
|
-- Check the Exhaust Gas Temperature Sensor 1 -G235-. Refer to EXHAUST GAS TEMPERATURE SENSOR 1 -G235-, CHECKING | |
| P054E Idle Control System - Fuel Quantity Lower Than Expected | Idle fuel control system comparison of actual and expected idle fuel quantity |
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING . | |
| P054F Idle Control System - Fuel Quantity Higher Than Expected | Idle fuel control system comparison of actual and expected idle fuel quantity |
|
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING . |
| P0562 System Voltage Low Voltage | Engine Off timer check power supply for "Engine Off Timer" |
|
|
|
|
-- Check the Voltage Supply input. |
| P0604 Internal Control Module Random Access Memory (RAM) Error | EEPROM Memory Error |
|
|
|
-- Replace the Engine Control Module (ECM) -J623- Refer to the Repair information for procedure. | |
| P0605 Internal Control Module ROM Test Error | ECM internal self test |
|
|
|
-- Replace the Engine Control Module (ECM) -J623- Refer to the Repair information for procedure. | |
| P0606 ECM/PCM Processor | Internal Control Module internal EEPROM Check |
|
|
|
-- Replace the Engine Control Module (ECM) -J623- Refer to the Repair information for procedure. | |
| Self-check of sensor IC CJ135 diagnosis, internal self test |
|
|
||||
| P0607 Control Module Performance | Control Module Performance internal self test |
|
|
|
-- Replace the Engine Control Module (ECM) -J623- Refer to the Repair information for procedure. | |
| P060C Internal Control Module Main Processor Performance | Engine control unit (ECU) internal self test |
|
|
|
-- Replace the Engine Control Module (ECM) -J623- Refer to the Repair information for procedure. | |
| P0627 Fuel Pump "A" Control Circuit/Open | Electric fuel pump output driver open circuit |
|
|
|
|
-- Check the Fuel Delivery Unit -GX1-. Refer to FUEL PUMP CONTROL MODULE - J538- / FUEL DELIVERY UNIT -GX1-, CHECKING |
| P0628 Fuel Pump "A" Control Circuit Low | Electric fuel pump output driver short to ground |
|
|
|
|
-- Check the Fuel Delivery Unit -GX1-. Refer to FUEL PUMP CONTROL MODULE - J538- / FUEL DELIVERY UNIT -GX1-, CHECKING OR |
| P0629 Fuel Pump "A" Control Circuit High | Electric fuel pump output driver short to battery plus |
|
|
|
|
-- Check the Fuel Delivery Unit -GX1-. Refer to FUEL PUMP CONTROL MODULE - J538- / FUEL DELIVERY UNIT -GX1-, CHECKING |
| P0634 PCM/ECM/TCM Internal Temperature Too High | ECM internal self test |
|
|
|
-- Replace the Engine Control Module (ECM) -J623- Refer to the Repair information for procedure. | |
| P0641 Sensor Reference Voltage "A" Circuit Open | Sensor Reference Voltage "A" signal range check high/low (APP-1, Diff.-pressure DPF sensor, Diff.-pressure LP-EGR, engine speed sensor (camshaft)) |
|
|
|
-- Replace the Engine Control Module (ECM) -J623- Refer to the Repair information for procedure. | |
| P064A Fuel Pump Control Module | Electric fuel pump electronics defective |
|
|
|
-- Check the Fuel Delivery Unit -GX1- Refer to FUEL PUMP CONTROL MODULE - J538- / FUEL DELIVERY UNIT -GX1-, CHECKING | |
| Electric fuel pump fuel pump electronics over temperature 1 |
|
|||||
| Electric fuel pump fuel pump electronics over temperature 2 |
|
|||||
| P064C Glow Plug Control Module | Glow Plug Time Control Module Circuit Wrong Calibration |
|
|
|
|
-- Check the Automatic Glow Time Control Module -J179-. Refer to.AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING |
|
|
|||||
| P0651 Sensor Reference Voltage "B" Circuit Open | Sensor Reference Voltage "B" signal range check high/low (Rail pressure sensor, Boost pressure sensor, Turbocharger position-sensor..) |
|
|
|
-- Replace the Engine Control Module (ECM) -J623- Refer to the Repair information for procedure. | |
| P066A Cylinder 1 Glow Plug Control Circuit Low | Glow Plug Cylinder 1 current check (overcurrent) glow plug #1 |
|
|
|
|
-- Check the Glow Plug 1 -QX1- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 1 -QX1-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P066C Cylinder 2 Glow Plug Control Circuit High | Glow Plug Cylinder 2 current check (overcurrent) glow plug #2 |
|
|
|
|
-- Check the Glow Plug 2 -QX2- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 2 -QX2-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P066E Cylinder 3 Glow Plug Control Circuit Low | Glow Plug Cylinder 3 current check (overcurrent) glow plug #3 |
|
|
|
|
-- Check the Glow Plug 3 -QX3- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 3 -QX3-, CHECKING .AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING |
| P0667 PCM / ECM / TCM Internal Temperature Sensor "A" Range/Performance | ECU temperature cross check of temperature sensors at cold start conditions |
|
|
|
|
-- Replace the Engine Control Module (ECM) -J623- Refer to the Repair information for procedure. |
| P0670 Glow Plug Module Control Circuit | Glow Plug Time Module Control Circuit open circuit / internal selftest GCU |
|
|
|
|
-- Check the Automatic Glow Time Control Module -J179-. Refer to.AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING |
| P0671 Cylinder 1 Glow Plug Circuit | current check glow plug #1 |
|
|
|
|
-- Check the Glow Plug 1 -QX1- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 1 -QX1-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P0672 Cylinder 2 Glow Plug Circuit | current check glow plug #2 |
|
|
|
|
-- Check the Glow Plug 2 -QX2- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 2 -QX2-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P0673 Cylinder 3 Glow Plug Circuit | current check glow plug #3 |
|
|
|
|
-- Check the Glow Plug 3 -QX3- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 3 -QX3-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P0674 Cylinder 4 Glow Plug Circuit | current check glow plug #4 |
|
|
|
|
-- Check the Glow Plug 4 -QX4- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 4 -QX4-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P067A Cylinder 4 Glow Plug Control Circuit Low | Glow Plug Cylinder 4 current check (overcurrent) glow plug #4 |
|
|
|
|
-- Check the Glow Plug 4 -QX4- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 4 -QX4-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P0684 Glow Plug Control Module to ECM Communication Circuit Range/Performance | Glow control unit monitoring of communication with glow control unit |
|
|
|
|
-- Check the Automatic Glow Time Control Module -J179-. Refer to AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| Glow control unit monitoring of supply voltage |
|
|
|
|||
| P068A ECM / PCM Power Relay De-Energized Performance - Too Early | ECM Power Relay Performance - monitoring the main relay's opening : too early opening |
|
|
|
-- Check the ECM Power Relay -J317-. | |
| P068B ECM / PCM Power Relay De-Energized Performance - Too Late | ECM Power Relay Performance - Stuck |
|
|
|
-- Check the ECM Power Relay -J317-. | |
| P0697 Sensor Reference Voltage "C" Circuit Open | Sensor Reference Voltage "C" signal range check high/low (Coolant temperature upstream engine..) |
|
|
|
-- Please unplug each Glow Plug one at a time and see if the fault will clear. If the fault clears replace the affected Glow Plug. If the fault will not clear please replace the Engine Control Module -J623-. Refer to the appropriate repair information. | |
| P06B9 Cylinder 1 Glow Plug Circuit Range/Performance | Glow Plug Cylinder 1 resistor check glow plug #1 |
|
|
|
|
-- Check the Glow Plug 1 -QX1- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 1 -QX1-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P06BA Cylinder 2 Glow Plug Circuit Range/Performance | Glow Plug Cylinder 2 resistor check glow plug #2 |
|
|
|
|
-- Check the Glow Plug 2 -QX2- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 2 -QX2-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P06BB Cylinder 3 Glow Plug Circuit Range/Performance | Glow Plug Cylinder 3 resistor check glow plug #3 |
|
|
|
|
-- Check the Glow Plug 3 -QX3- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 3 -QX3-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P06BC Cylinder 4 Glow Plug Circuit Range/Performance | Glow Plug Cylinder 4 resistor check glow plug #4 |
|
|
|
|
-- Check the Glow Plug 4 -QX4- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 4 -QX4-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P06C5 Cylinder 1 Glow Plug Incorrect | Glow Plug Cylinder 1 check glow plug type #1 |
|
|
|
|
-- Check the Glow Plug 1 -QX1- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 1 -QX1-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P06C6 Cylinder 2 Glow Plug Incorrect | Glow Plug Cylinder 2 check glow plug type #2 |
|
|
|
|
-- Check the Glow Plug 2 -QX2- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 2 -QX2-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P06C7 Cylinder 3 Glow Plug Incorrect | Glow Plug Cylinder 3 check glow plug type #3 |
|
|
|
|
-- Check the Glow Plug 3 -QX3- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 3 -QX3-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P06C8 Cylinder 4 Glow Plug Incorrect | Glow Plug Cylinder 4 check glow plug type #4 |
|
|
|
|
-- Check the Glow Plug 4 -QX4- and the Automatic Glow Time Control Module -J179-. Refer to GLOW PLUG 4 -QX4-, CHECKING / AUTOMATIC GLOW TIME CONTROL MODULE - J179- AND GLOW PLUG, CHECKING . |
| P1004 Torque Difference Cylinder 1: Limit Value Exceeded | Torque inner control loop comparison of actual and desired torque (positve and negative control error) cylinder #1 |
|
|
|
|
-- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING .-- Check Fuel Injectors --. Refer to FUEL INJECTOR --, CHECKING . |
| P1005 Torque Difference Cylinder 2: Limit Value Exceeded | Torque inner control loop comparison of actual and desired torque (positve and negative control error) cylinder #2 |
|
|
|
|
-- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING .-- Check Fuel Injectors --. Refer to FUEL INJECTOR --, CHECKING . |
| P1006 Torque Difference Cylinder 3: Limit Value Exceeded | Torque inner control loop comparison of actual and desired torque (positve and negative control error) cylinder #3 |
|
|
|
|
-- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING .-- Check Fuel Injectors --. Refer to FUEL INJECTOR --, CHECKING . |
| P1007 Torque Difference Cylinder 4: Limit Value Exceeded | Torque inner control loop comparison of actual and desired torque (positve and negative control error) cylinder #4 |
|
|
|
|
-- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING .-- Check Fuel Injectors --. Refer to FUEL INJECTOR --, CHECKING . |
| P13CE Cylinder 1 Pressure Sensor Circuit electrical fault | Cylinder 1 Pressure Sensor Circuit signal range check high sensor #1 |
|
|
|
|
-- Check the Glow Plug 1 -QX1-. Refer to GLOW PLUG 1 -QX1-, CHECKING . |
| P13CF Cylinder 1 Pressure Sensor Circuit Short to earth | Cylinder 1 Pressure Sensor Circuit signal range check low sensor #1 |
|
|
|
|
-- Check the Glow Plug 1 -QX1-. Refer to GLOW PLUG 1 -QX1-, CHECKING . |
| P13D0 Cylinder 1 Pressure Sensor Implausible Signal | Cylinder 1 Pressure Sensor physical signal out of range sensor #1 |
|
|
|
|
-- Check the Glow Plug 1 -QX1-. Refer to GLOW PLUG 1 -QX1-, CHECKING . |
| Cylinder 1 Pressure Sensor plausibility check: constant cylinder pressure signal sensor #1 |
|
|
||||
| Cylinder 1 pressure sensor plausibility check: pressure offset sensor #1 |
|
|
||||
| Cylinder 1 pressure sensor plausibility with calculated cylinder pressure sensor #1 |
|
|
|
|||
| P13D1 Cylinder 2 Pressure Sensor Circuit electrical fault | Cylinder 2 Pressure Sensor signal range check high sensor #2 |
|
|
|
|
-- Check the Glow Plug 2 -QX2-. Refer to GLOW PLUG 2 -QX2-, CHECKING . |
| P13D2 Cylinder 2 Pressure Sensor Circuit Short to earth | Cylinder 2 Pressure Sensor signal range check low sensor #2 |
|
|
|
|
-- Check the Glow Plug 2 -QX2-. Refer to GLOW PLUG 2 -QX2-, CHECKING . |
| P13D3 Cylinder 2 Pressure Sensor Implausible Signal | Cylinder 2 Pressure Sensor physical signal out of range sensor #2 |
|
|
|
|
-- Check the Glow Plug 2 -QX2-. Refer to GLOW PLUG 2 -QX2-, CHECKING . |
| Cylinder 2 Pressure Sensor plausibility check: constant cylinder pressure signal sensor #2 |
|
|
||||
| Cylinder 2 pressure sensor plausibility check: pressure offset sensor #2 |
|
|
||||
| Cylinder 2 pressure sensor plausibility with calculated cylinder pressure sensor #2 |
|
|
|
|||
| P13D4 Cylinder 3 Pressure Sensor Circuit electrical fault | Cylinder 3 Pressure Sensor signal range check high sensor #3 |
|
|
|
|
-- Check the Glow Plug 3 -QX3-. Refer to GLOW PLUG 3 -QX3-, CHECKING . |
| P13D5 Cylinder 3 Pressure Sensor Circuit Short to earth | Cylinder 3 Pressure Sensor signal range check low sensor #3 |
|
|
|
|
-- Check the Glow Plug 3 -QX3-. Refer to GLOW PLUG 3 -QX3-, CHECKING . |
| P13D6 Cylinder 3 Pressure Sensor Implausible Signal | Cylinder 3 Pressure Sensor physical signal out of range sensor #3 |
|
|
|
|
-- Check the Glow Plug 3 -QX3-. Refer to GLOW PLUG 3 -QX3-, CHECKING . |
| Cylinder 3 Pressure Sensor plausibility check: constant cylinder pressure signal sensor #3 |
|
|
||||
| Cylinder 3 pressure sensor plausibility check: pressure offset sensor #3 |
|
|
||||
| Cylinder 3 pressure sensor plausibility with calculated cylinder pressure sensor #3 |
|
|
|
|||
| P13D7 Cylinder 4 Pressure Sensor Circuit electrical fault | Cylinder 4 Pressure Sensor signal range check high sensor #4 |
|
|
|
|
-- Check the Glow Plug 4 -QX4-. Refer to GLOW PLUG 4 -QX4-, CHECKING . |
| P13D8 Cylinder 4 Pressure Sensor Circuit Short to earth | Cylinder 4 Pressure Sensor signal range check low sensor #4 |
|
|
|
|
-- Check the Glow Plug 4 -QX4-. Refer to GLOW PLUG 4 -QX4-, CHECKING . |
| P13D9 Cylinder 4 Pressure Sensor Implausible Signal | Cylinder 4 Pressure Sensor physical signal out of range sensor #4 |
|
|
|
|
-- Check the Glow Plug 4 -QX4-. Refer to GLOW PLUG 4 -QX4-, CHECKING . |
| Cylinder 4 Pressure Sensor plausibility check: constant cylinder pressure signal sensor #4 |
|
|
||||
| Cylinder 4 pressure sensor plausibility check: pressure offset sensor #4 |
|
|
||||
| Cylinder 4 pressure sensor plausibility with calculated cylinder pressure sensor #4 |
|
|
|
|||
| P13E0 Cylinder 1 Pressure Sensor Circuit Malfunction | Cylinder 1 Pressure Sensor plausibility check of position TDC cylinder #1 |
|
|
|
|
-- Check the Glow Plug 1 -QX1-. Refer to GLOW PLUG 1 -QX1-, CHECKING . -- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING . |
| P13E1 Cylinder 2 Pressure Sensor Circuit Malfunction | Cylinder 2 Pressure Sensor plausibility check of position TDC cylinder #2 |
|
|
|
|
-- Check the Glow Plug 2 -QX2-. Refer to GLOW PLUG 2 -QX2-, CHECKING . -- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING . |
| P13E2 Cylinder 3 Pressure Sensor Circuit Malfunction | Cylinder 3 Pressure Sensor plausibility check of position TDC cylinder #3 |
|
|
|
|
-- Check the Glow Plug 3 -QX3-. Refer to GLOW PLUG 3 -QX3-, CHECKING . -- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING . |
| P13E3 Cylinder 4 Pressure Sensor Circuit Malfunction | Cylinder 4 Pressure Sensor plausibility check of position TDC cylinder #4 |
|
|
|
|
-- Check the Glow Plug 4 -QX4-. Refer to GLOW PLUG 4 -QX4-, CHECKING . -- Check Engine Speed (RPM) Sensor -G28-. Refer to ENGINE SPEED SENSOR - G28-, CHECKING . |
| P146D Confirmation of heating one of the reducing agents Short to Plus | SCR heater circuit 1 (AdBlue tank) short cut to battery plus, current sensor |
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING | |
| P146F Confirmation of heating for 2 reducing agent Short to Plus | SCR heater circuit 2 (AdBlue line, dosing unit) short to battery plus, current sensor |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P148B Output stage for heating the reducing agents malfunction | SCR heater control circuit 1 external short to battery plus |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P148C End stage 2 for reducing agent heating Faulty | SCR heater control circuit 2 external short at pressure line heater |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P16BA Coolant pump for charge air cooling Dry run | Water pump for charge air intercooler running dry |
|
|
|
-- Check the Charge Air Cooling Pump -V188-. Refer to CHARGE AIR COOLING PUMP -V188-, CHECKING | |
| P16C6 Heater support pump Dry running | Electric coolant pump coolant pump running-dry |
|
|
|
|
-- Check the Heater Support Pump -V488-. Refer to HEATER SUPPORT PUMP -V488-, CHECKING |
| P16C7 Heater support pump locked | Electric coolant pump coolant pump blocked |
|
|
|
-- Check the Heater Support Pump -V488-. Refer to HEATER SUPPORT PUMP -V488-, CHECKING | |
| P16C8 Heater support pump Overheated | Electric coolant pump coolant pump overheated |
|
|
|
-- Check the Heater Support Pump -V488-. Refer to HEATER SUPPORT PUMP -V488-, CHECKING | |
| P16C9 Heater support pump Engine speed too low | Electric coolant pump min speed not reached |
|
|
|
-- Check the Heater Support Pump -V488-. Refer to HEATER SUPPORT PUMP -V488-, CHECKING | |
| P169A Transport Mode Active | Transport Mode Active |
|
|
|
|
-- Mode can be deactivated with a factory scan tool or will automatically turn off after vehicle accumulates the first 100 miles of driving. |
| P199C Coolant pump for cylinder head Short to Plus | Main coolant pump short to battery plus |
|
|
|
|
-- Check the Cylinder Head Coolant Valve -N489-. Refer to CYLINDER HEAD COOLANT VALVE -N489-, CHECKING |
| P199D Coolant pump for cylinder head Short to earth | Main coolant pump short to ground |
|
|
|
|
-- Check the Cylinder Head Coolant Valve -N489-. Refer to CYLINDER HEAD COOLANT VALVE -N489-, CHECKING |
| P199E Coolant pump for cylinder head open | Main coolant pump open circuit |
|
|
|
|
-- Check the Cylinder Head Coolant Valve -N489-. Refer to CYLINDER HEAD COOLANT VALVE -N489-, CHECKING |
| P20BB Reductant Heater "A" Control Circuit Low | SCR heater circuit 1 (AdBlue tank) short cut to ground |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P20BC Reductant Heater "A" Control Circuit High | SCR heater circuit 1 (AdBlue tank) short cut to battery plus |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P20BD Reductant Heater "B" Control Circuit/Open | SCR heater circuit 2 (AdBlue line, dosing unit) open circuit |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P20BF Reductant Heater "B" Control Circuit Low | SCR heater circuit 2 (AdBlue line, dosing unit) short to ground |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P20B7 Reductant Metering Unit Heater Control Circuit Low | SCR heater control circuit 2 open load in pressure line heater |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P20B8 Reductant Metering Unit Heater Control Circuit High | SCR heater control circuit 2 short circuit in pressure line heater |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P20B9 Reductant Heater "A" Control Circuit/Open | SCR heater circuit 1 (AdBlue tank) open circuit |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P20C0 Reductant Heater "B" Control Circuit High | SCR heater circuit 2 (AdBlue line, dosing unit) short to battery plus |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P20E8 Reductant Pressure Too Low | Urea dosing pressure build up fault |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| Urea dosing pressure under pressure error during pressure control operation (fast debouncing of lower min pressure threshold) |
|
|
|
|||
| Urea dosing pressure under pressure error during pressure control operation (slow debouncing of upper min pressure threshold) |
|
|
|
|||
| P20E9 Reductant Pressure Too High | Urea dosing pressure over pressure monitoring fast |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| Urea dosing pressure over pressure monitoring slow |
|
|
|
|
||
| P20EA Reductant Control Module Power Relay De-Energized Performance - Too Early | SCR-relay relay stuck in open position |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| P20EB Reductant Control Module Power Relay De-Energized Performance - Too Late | SCR-relay relay stuck in closed position |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| P20FA Reductant Pump "B" Control Circuit/Open | Urea backflow pump open circuit |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| P20FB Reductant Pump "B" Control Performance/Stuck Off | Urea dosing pressure decrease fault |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| P20FC Reductant Pump "B" Control Circuit Low | Urea backflow pump short cut to ground low side |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| P20FD Reductant Pump "B" Control Circuit High | Urea backflow pump short cut to battery low side |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| P202A Reductant Tank Heater Control Circuit/Open | SCR heater control circuit 1 rationality check |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P202B Reductant Tank Heater Control Circuit Low | SCR heater control circuit 1 conductance too low /open circuit |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P202C Reductant Tank Heater Control Circuit High | SCR heater control circuit 1 short in heater element |
|
|
|
|
-- Check the Reducing Agent Heater Control Module -J891- Refer to REDUCING AGENT HEATER CONTROL MODULE -J891-, CHECKING |
| P2002 Particulate Trap Bank 1 Efficiency Below Threshold | Particulate matter trap, filtering performance evaluating LP EGR filter pressure drop |
|
|
|
|
-- Regeneration Service must be performed. Refer to appropriate repair information. -- Check the Differential Pressure Sensor -G505-. Refer to DIFFERENTIAL PRESSURE SENSOR - G505-, CHECKING . -- Check the Exhaust Pressure Sensor 1 -G450-. Refer to EXHAUST PRESSURE SENSOR 1 -G450-, CHECKING . |
| P2031 Exhaust Gas Temperature Sensor 2, Bank 1 Circuit | Exhaust Gas Temperature Sensor signal range check high |
|
|
|
-- Check the Exhaust Gas Temperature Sensor 3 -G495-. Refer to EXHAUST GAS TEMPERATURE SENSOR 3 -G495-, CHECKING . | |
| P2032 Exhaust Gas Temperature Sensor 2, Bank 1 Circuit | Exhaust Gas Temperature Sensor Short to Ground |
|
|
|
-- Check the Exhaust Gas Temperature Sensor 3 -G495-. Refer to EXHAUST GAS TEMPERATURE SENSOR 3 -G495-, CHECKING | |
| P203A Reductant Level Sensor "A" Circuit Low | Urea level sensor pattern of the pulse width modulation signal (level sensor) |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| P203B Reductant Level Sensor "A" Circuit Range/Performance | Urea level sensor monitoring level senor signal / SRC max, SRC min |
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING | |
| Urea level sensor no echo |
|
|
|
|
||
| P203C Reductant Level Sensor "A" Circuit Low | Urea level sensor constant Low signal (current supply, line fault) |
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING | |
| P203D Reductant Level Sensor "A" Circuit High | Urea level sensor constant High signal (open loop, line fault) |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| P2047 Reductant Injection Valve Circuit/Open Bank 1 Unit 1 | Urea dosing valve open circuit low side |
|
|
|
-- Check the Reducing Agent Injector -N474- Refer to REDUCING AGENT INJECTOR -N474-, CHECKING | |
| P2048 Reductant Injection Valve Circuit Low Bank 1 Unit 1 | Urea dosing valve short cut to ground low side |
|
|
|
-- Check the Reducing Agent Injector -N474- Refer to REDUCING AGENT INJECTOR -N474-, CHECKING | |
| P2049 Reductant Injection Valve Circuit High Bank 1 Unit 1 | Urea dosing valve short cut to battery low side |
|
|
|
-- Check the Reducing Agent Injector -N474- Refer to REDUCING AGENT INJECTOR -N474-, CHECKING | |
| P204F Reductant System Performance Bank 1 | SCR catalyst efficiency monitoring of NOx conversion efficiency |
|
|
|
|
-- Check the NOx Sensor Control Module -J583-. Refer to NOx SENSOR CONTROL MODULE - J583 -, CHECKING |
| P205B Reductant Tank Temperature Sensor Circuit Range/Performance | Urea tank temperature sensor monitoring temperature sensor signal (signal range check) |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| Urea tank temperature sensor plausibility check (liquid media recognized, tank temperature below freeze point) |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING | |
| Urea tank temperature sensor rationality |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING | |
| P206B Reductant Quality Sensor Circuit Range/Performance | Urea quality sensor plausibility of urea |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| P207F Reductant Quality Performance | SCR wrong medium monitor monitoring of DEF quality with quality sensor |
|
|
|
|
-- Check the NOx Sensor Control Module -J583-. Refer to NOx SENSOR CONTROL MODULE - J583 -, CHECKING |
| P208A Reductant Pump "A" Control Circuit/Open | Urea dosing pump open circuit |
|
|
|
-- Check the Reducing Agent Injector -N474- Refer to REDUCING AGENT INJECTOR -N474-, CHECKING | |
| P208B Reductant Pump "A" Control Performance/Stuck Off | Urea dosing pump monitoring coil current during cold start |
|
|
|
|
-- Check the Reducing Agent Injector -N474- Refer to REDUCING AGENT INJECTOR -N474-, CHECKING |
| Urea dosing pump monitoring of MSP (mechanical stop of solenoid pump) and BMP (begin of moving point); MSP and/or BMP not recognized | Failure counter for BMP or MSP incremented if:
|
|
|
|
-- Check the Reducing Agent Injector -N474- Refer to REDUCING AGENT INJECTOR -N474-, CHECKING | |
| P208C Reductant Pump "A" Control Circuit Low | Urea dosing pump short cut to ground low side |
|
|
|
-- Check the Reducing Agent Injector -N474- Refer to REDUCING AGENT INJECTOR -N474-, CHECKING | |
| P208D Reductant Pump "A" Control Circuit High | Urea dosing pump short cut to battery low side |
|
|
|
-- Check the Reducing Agent Injector -N474- Refer to REDUCING AGENT INJECTOR -N474-, CHECKING | |
| P208E Reductant Injection Valve Stuck Closed Bank 1 Unit 1 | Urea dosing valve monitoring the valve opening, identification of begin of injection period (BIP) via valve driver |
|
|
|
|
-- Check the Reducing Agent Injector -N474- Refer to REDUCING AGENT INJECTOR -N474-, CHECKING |
| P218F Reductant No Flow Detected | First filling procedure of SCR system not finished after replacement at workshop functional check |
|
|
|
|
-- Check SCR fluid level. Refer to appropriate repair information. |
| P220A NOx Sensor Supply Voltage Circuit Bank 1 Sensor 1 | NOx sensor upstream SCR catalyst sensor supply voltage |
|
|
|
|
-- Check the NOx Sensor Control Module -J583-. Refer to NOx SENSOR CONTROL MODULE - J583 -, CHECKING |
| P2080 Exhaust Gas Temperature Sensor Circuit Bank1 Range/Performance | Exhaust gas temperature sensor upstream turbine comparison of exhaust gas temperature sensor upstream turbine with model value |
|
|
|
|
-- Check the Exhaust Gas Temperature Sensor 1 -G235-. Refer to.EXHAUST GAS TEMPERATURE SENSOR 1 -G235-, CHECKING |
| Exhaust gas temperature sensor upstream turbocharger cross check of temperature sensors (exhaust part) at cold start conditions |
|
|
|
|||
| P2084 Exhaust Gas Temperature Sensor 2 Circuit Range/Performance | Exhaust gas temperature sensor upstream DOC comparison of exhaust gas temperature sensor upstream oxidation catalyst with model value |
|
|
|
|
-- Check the Exhaust Gas Temperature Sensor 2 -G448-. Refer to EXHAUST GAS TEMPERATURE SENSOR 2 -G448-, CHECKING |
| Exhaust gas temperature sensor upstream turbocharger cross check of temperature sensors (exhaust part) at cold start conditions |
|
|
|
|||
| P21CE Reductant Quality Module Performance | Urea quality sensor release |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING . |
| P21C7 Reductant Control Module Power Relay/Relays Control Circuit/Open | SCR-relay open loop |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| P21C8 Reductant Control Module Power Relay/Relays Control Circuit Low | SCR-relay short to ground |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| P21C9 Reductant Control Module Power Relay/Relays Control Circuit High | SCR-relay short to battery |
|
|
|
|
-- Check the Reducing Agent Metering System Delivery Unit -GX19- Refer to REDUCING AGENT METERING SYSTEM DELIVERY UNIT -GX19-, CHECKING |
| P2100 Throttle Actuator Control Motor Circuit/Open | Throttle Valve Actuator open load |
|
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING . |
| P2101 Throttle Actuator Control Motor Circuit Range/performance | Throttle Valve Actuator short circuit over load |
|
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING . |
| P2102 Throttle Actuator Control Motor Circuit Low | Throttle Valve Actuator Short to Ground |
|
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING . |
| P2103 Throttle Actuator "A" Control Motor Circuit High | Throttle Valve Actuator Short to Battery voltage |
|
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING . |
| P2111 Throttle Actuator Control System - Stuck Open | Throttle valve position control loop comparison of actual and desired position signal |
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING . | |
| P2112 Throttle Actuator Control System - Stuck closed | Throttle valve position control loop comparison of actual and desired position signal |
|
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING . |
| P2122 Throttle / Pedal Position Sensor / Switch D Circuit Low Input | Accelerator pedal position sensor signal range check low |
|
|
|
|
-- Check the Accelerator Pedal Module -GX2-. Refer to ACCELERATOR PEDAL MODULE - GX2-, CHECKING . |
| P2123 Throttle / Pedal Position Sensor / Switch D Circuit High Input | Accelerator pedal position sensor signal range check high |
|
|
|
|
-- Check the Accelerator Pedal Module -GX2-. Refer to ACCELERATOR PEDAL MODULE - GX2-, CHECKING . |
| P2127 Throttle / Pedal Position Sensor / Switch E Circuit Low Input | Accelerator pedal position sensor signal range check low |
|
|
|
|
-- Check the Accelerator Pedal Module -GX2-. Refer to ACCELERATOR PEDAL MODULE - GX2-, CHECKING . |
| P2128 Throttle / Pedal Position Sensor / Switch E Circuit High Input | Accelerator pedal position sensor signal range check high |
|
|
|
|
-- Check the Accelerator Pedal Module -GX2-. Refer to ACCELERATOR PEDAL MODULE - GX2-, CHECKING . |
| P2138 Throttle / Pedal Position Sensor/Switch D/E Voltage Correlation | Accelerator pedal position sensor plausibility check |
|
|
|
-- Check the Accelerator Pedal Module -GX2-. Refer to ACCELERATOR PEDAL MODULE - GX2-, CHECKING . | |
| P2146 Fuel Injector Group "A" Supply Voltage Circuit/Open | Injector Supply Voltage Open Circuit |
|
|
|
|
-- Check Fuel Injectors --. Refer to FUEL INJECTOR --, CHECKING . |
| P2149 Fuel Injector Group "B" Supply Voltage Circuit/Open | Injector Supply Voltage Open Circuit |
|
|
|
|
-- Check Fuel Injectors --. Refer to FUEL INJECTOR --, CHECKING . |
| P2173 Throttle Actuator Control System - High Airflow Detected | Throttle valve monitoring differential pressure across throttle valve |
|
|
|
|
-- Check the Throttle Valve Control Module -GX3-. Refer to THROTTLE VALVE CONTROL MODULE - GX3-, CHECKING . |
| P2183 Engine Coolant Temperature Sensor 2 Circuit Range/Performance | Engine Coolant Temperature Sensor On Radiator cross check of temperature sensors (engine part) at cold start conditions |
|
|
|
|
-- Check the Engine Coolant Temperature Sensor On Radiator Outlet -G83-. Refer to ENGINE COOLANT TEMPERATURE SENSOR ON RADIATOR OUTLET -G83-, CHECKING . |
| P2184 Engine Coolant Temperature Sensor 2 Circuit Low | Engine Coolant Temperature Sensor On Radiator Outlet signal range check low |
|
|
|
-- Check the Engine Coolant Temperature Sensor On Radiator Outlet -G83-. Refer to ENGINE COOLANT TEMPERATURE SENSOR ON RADIATOR OUTLET -G83-, CHECKING . | |
| P2185 Engine Coolant Temperature Sensor 2 Circuit High | Engine Coolant Temperature Sensor On Radiator Outlet Circuit signal range check high |
|
|
|
-- Check the Engine Coolant Temperature Sensor On Radiator Outlet -G83-. Refer to ENGINE COOLANT TEMPERATURE SENSOR ON RADIATOR OUTLET -G83-, CHECKING . | |
| P2195 O2 Sensor Signal Stuck Lean Bank 1 Sensor 1 | O2 Sensor Signal Plausibility check with calculated oxygen concentration (airflow quantity and fuel quantity) |
|
|
|
|
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to OXYGEN SENSOR 1 BEFORE CATALYTIC CONVERTER -GX10-, CHECKING . |
| P2196 O2 Sensor Signal Stuck Rich Bank 1 Sensor 1 | O2 Sensor Signal Biased/Stuck Rich Bank 1 Sensor 1 |
|
|
|
|
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to OXYGEN SENSOR 1 BEFORE CATALYTIC CONVERTER -GX10-, CHECKING . |
| P2200 NOx Sensor Bank 1 Sensor 1 Circuit | NOx sensor upstream SCR catalyst open circuit/ short cut |
|
|
|
|
-- Check the NOx Sensor Control Module -J583-. Refer to NOx SENSOR CONTROL MODULE - J583 -, CHECKING |
| P2201 NOx Sensor Circuit Range/Performance Bank 1 Sensor 1 | NOx Sensor Circuit NOx offset signal range check low/high |
|
|
|
|
-- Check the NOx Sensor Control Module -J583-. Refer to NOx SENSOR CONTROL MODULE - J583 -, CHECKING |
| Dynamic check |
|
|
|
|||
| monitoring of NOx undershoot during fuel cut off |
|
|
|
|||
| plausibility of NOx sensor upstream SCR-catalyst |
|
|
|
|||
| P2202 NOx Sensor Bank 1 Sensor 1 Circuit Low | NOx sensor upstream SCR catalyst signal range check low |
|
|
|
|
-- Check the NOx Sensor Control Module -J583-. Refer to NOx SENSOR CONTROL MODULE - J583 -, CHECKING |
| P2203 NOx Sensor Bank 1 Sensor 1 Circuit High | NOx sensor upstream SCR catalyst signal range check high |
|
|
|
|
-- Check the NOx Sensor Control Module -J583-. Refer to NOx SENSOR CONTROL MODULE - J583 -, CHECKING |
| P2209 NOx Sensor Heater Sense Bank 1 Sensor 1 Circuit Range/Performance | NOx sensor upstream SCR catalyst timeout of 'readiness for operation' |
|
|
|
|
-- Check the NOx Sensor Control Module -J583-. Refer to NOx SENSOR CONTROL MODULE - J583 -, CHECKING |
| P2237 O2 Sensor Positive Current Control Circuit Bank 1 Sensor 1 Open | O2 Sensor Positive Current Control pump cell transition check - circuit continuity |
|
|
|
|
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to OXYGEN SENSOR 1 BEFORE CATALYTIC CONVERTER -GX10-, CHECKING . |
| P2243 O2 Sensor Reference Voltage Circuit Bank 1 Sensor 1 Open | O2 Sensor Reference Voltage nernst cell transition check for hot sensor - circuit continuity |
|
|
|
|
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to OXYGEN SENSOR 1 BEFORE CATALYTIC CONVERTER -GX10-, CHECKING . |
| P2251 O2 Sensor Negative Current Control Circuit Bank 1 Sensor 1 open | O2 Sensor Negative Current nernst and pump cell transition check - circuit continuity |
|
|
|
|
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to OXYGEN SENSOR 1 BEFORE CATALYTIC CONVERTER -GX10-, CHECKING . |
| P226C Turbocharger Boost Control "A" Slow Response | Turbocharger Boost Control "A" Slow Response check of dynamic response of the boost pressure (positive gradient of desired boost pressure) |
|
|
|
|
-- Check the Wastegate Bypass Regulator Valve -N75-. Refer to WASTEGATE BYPASS REGULATOR VALVE -N75-, CHECKING . |
| P2279 Intake Air System Leak | Intake Air System Leak plausibility check by model air mass |
|
|
|
|
-- Check for leaking engine gaskets, oil cap not installed properly or leak in the intake duct after the Mass Air Flow sensor. |
| P2294 Fuel Pressure Regulator 2 Control Circuit | Fuel Pressure control Valve / fuel pressure regulator Circuit Open |
|
|
|
|
-- Check the Fuel Metering Valve -N290-. Refer to FUEL METERING VALVE -N290-, CHECKING . |
| P2295 Fuel Pressure Regulator 2 Control Circuit Low | Fuel Pressure control Valve / fuel pressure regulator Shorted to Ground |
|
|
|
|
-- Check the Fuel Metering Valve -N290-. Refer to FUEL METERING VALVE -N290-, CHECKING . |
| P2296 Fuel Pressure Regulator 2 Control Circuit High | Fuel Pressure control Valve / fuel pressure regulator Shorted to Battery Voltage |
|
|
|
|
-- Check the Fuel Metering Valve -N290-. Refer to FUEL METERING VALVE -N290-, CHECKING . |
| P240F Exhaust Gas Recirculation Slow Response | EGR slow response comparison of desired and measured air mass flow |
|
|
|
|
-- Check the EGR Valve 1 -GX5-. Refer to EGR VALVE 1 - GX5 -, CHECKING . -- Check the EGR Valve 2 -GX6-. Refer to EGR VALVE 2 -GX6-, CHECKING . |
|
|
|||||
| P241F EGR Cooler "B" Efficiency Below Threshold | Low-pressure EGR cooler / cooler performance comparison of EGR cooler efficiency to efficiency threshold |
|
|
|
|
-- Check the EGR Valve 2 -GX6-. Refer to EGR VALVE 2 -GX6-, CHECKING |
| P242A Exhaust Gas Temperature Sensor Circuit Bank 1 Sensor 3 | Exhaust gas temperature sensor upstream PM trap signal range check high |
|
|
|
-- Check the Exhaust Gas Temperature Sensor 3 -G495-. Refer to EXHAUST GAS TEMPERATURE SENSOR 3 -G495-, CHECKING . | |
| P242B Exhaust Gas Temperature Sensor Circuit Bank 1 Sensor 3 Range/Performance | Exhaust gas temperature sensor upstream PM trap cross check of temperature sensors (exhaust part) at cold start conditions |
|
|
|
-- Check the Exhaust Gas Temperature Sensor 3 -G495-. Refer to EXHAUST GAS TEMPERATURE SENSOR 3 -G495-, CHECKING . | |
| P242C Exhaust Gas Temperature Sensor Circuit Low Bank 1 Sensor 3 | Exhaust gas temperature sensor upstream PM trap signal range check low |
|
|
|
-- Check the Exhaust Gas Temperature Sensor 3 -G495-. Refer to EXHAUST GAS TEMPERATURE SENSOR 3 -G495-, CHECKING | |
| P244C Exhaust Temperature Too Low For Particulate Filter Regeneration Bank 1 | Exhaust temperature control loop (temperature upstream turbine) TTCL of temperature upstream turbine |
|
|
|
|
-- Check the Exhaust Gas Temperature Sensors --. Refer to EXHAUST GAS TEMPERATURE SENSOR 1 -G235-, CHECKING /EXHAUST GAS TEMPERATURE SENSOR 2 -G448-, CHECKING EXHAUST GAS TEMPERATURE SENSOR 3 -G495-, CHECKING /EXHAUST GAS TEMPERATURE SENSOR 4 -G648-, CHECKING . |
|
|
|
||||
| P2452 Diesel Particulate Filter Differential Pressure Sensor Circuit | Relative pressure sensor upstream particulate matter trap signal range check high |
|
|
|
|
-- Check the Differential Pressure Sensor -G505-. Refer to DIFFERENTIAL PRESSURE SENSOR - G505-, CHECKING . -- Check the Exhaust Pressure Sensor 1 -G450-. Refer to EXHAUST PRESSURE SENSOR 1 -G450-, CHECKING . |
| P2453 Diesel Particulate Filter Differential Pressure Sensor Circuit Range/Performance | Exhaust Pressure Sensor Circuit Offset detection during afterrun |
|
|
|
|
-- Check the Differential Pressure Sensor -G505-. Refer to DIFFERENTIAL PRESSURE SENSOR - G505-, CHECKING . -- Check the Exhaust Pressure Sensor 1 -G450-. Refer to EXHAUST PRESSURE SENSOR 1 -G450-, CHECKING . |
| P2454 Diesel Particulate Filter Differential Pressure Sensor Circuit Low | Relative pressure sensor upstream particulate matter trap signal range check low |
|
|
|
|
-- Check the Differential Pressure Sensor -G505-. Refer to DIFFERENTIAL PRESSURE SENSOR - G505-, CHECKING . -- Check the Exhaust Pressure Sensor 1 -G450-. Refer to EXHAUST PRESSURE SENSOR 1 -G450-, CHECKING . |
| P2456 Diesel Particulate Filter Pressure Sensor "A" Circuit Intermittent/Erratic | Relative pressure sensor upstream particulate matter trap dynamic plausibility of the pressure sensor signal |
|
|
|
|
-- Check the Differential Pressure Sensor -G505-. Refer to DIFFERENTIAL PRESSURE SENSOR - G505-, CHECKING . -- Check the Exhaust Pressure Sensor 1 -G450-. Refer to EXHAUST PRESSURE SENSOR 1 -G450-, CHECKING . |
| Relative pressure sensor upstream particulate matter trap dynamic plausibility of the differential pressure signal |
|
|
|
|||
| P2458 Diesel Particulate Filter Regeneration Duration | Particulate matter trap, incomplete regeneration particulate matter trap regeneration time exceeds maximum threshold |
|
|
|
|
-- Regeneration Service must be performed. Refer to appropriate repair information. -- Check the Differential Pressure Sensor -G505-. Refer to DIFFERENTIAL PRESSURE SENSOR - G505-, CHECKING . -- Check the Exhaust Pressure Sensor 1 -G450-. Refer to EXHAUST PRESSURE SENSOR 1 -G450-, CHECKING . |
| P2459 Diesel Particulate Filter Regeneration Frequency | Diesel Particulate Filter Regeneration Frequency comparison of particulate matter trap loading calculated from engine particulate matter emissions with particulate matter trap loading calculated from differential pressure at the beginning of particulate matter trap regeneration |
|
|
|
|
-- Regeneration Service must be performed. Refer to appropriate repair information.-- Check the Differential Pressure Sensor -G505-. Refer to DIFFERENTIAL PRESSURE SENSOR - G505-, CHECKING /.-- Check the Exhaust Pressure Sensor 1 -G450-. Refer to EXHAUST PRESSURE SENSOR 1 -G450-, CHECKING |
| P2463 Diesel Particulate Filter - Soot Accumulation | Particulate matter trap calculated particulate matter trap loading exceeds maximum threshold |
|
|
|
-- Regeneration Service must be performed. Refer to appropriate repair information.-- Check the Differential Pressure Sensor -G505-. Refer to DIFFERENTIAL PRESSURE SENSOR - G505-, CHECKING /.-- Check the Exhaust Pressure Sensor 1 -G450-. Refer to EXHAUST PRESSURE SENSOR 1 -G450-, CHECKING | |
| P246E Exhaust Gas Temperature Sensor Circuit Bank 1 Sensor 4 | Exhaust gas temperature sensor downstream PM trap signal range check high |
|
|
|
-- Check the Exhaust Gas Temperature Sensor 4 -G648-. Refer to EXHAUST GAS TEMPERATURE SENSOR 4 -G648-, CHECKING . | |
| P246F Exhaust Gas Temperature Sensor Circuit Bank 1 Sensor 4 Range/Performance | Exhaust gas temperature sensor downstream PM trap comparison of exhaust gas temperature sensor downstream particulate matter trap with model value |
|
|
|
|
-- Check the Exhaust Gas Temperature Sensor 4 -G648-. Refer to EXHAUST GAS TEMPERATURE SENSOR 4 -G648-, CHECKING . |
| Exhaust gas temperature sensor downstream PM trap cross check of temperature sensors (exhaust part) at cold start conditions |
|
|
|
|||
| P2470 Exhaust Gas Temperature Sensor Circuit Low Bank 1 Sensor 4 | Exhaust gas temperature sensor downstream PM trap signal range check low |
|
|
|
-- Check the Exhaust Gas Temperature Sensor 4 -G648-. Refer to EXHAUST GAS TEMPERATURE SENSOR 4 -G648-, CHECKING | |
| P2478 Exhaust Gas Temperature Out of Range Bank 1 Sensor 1 | Exhaust temperature control loop comparison of actual and desired temperature upstream turbine (positive and negative control deviation) |
|
|
|
|
-- Check the Exhaust Gas Temperature Sensor 1 -G235-. Refer to EXHAUST GAS TEMPERATURE SENSOR 1 -G235-, CHECKING |
| Exhaust temperature control loop number of regeneration interruptions due to temperature upstream turbine too high (>860°C) |
|
|
|
|||
| P247A Exhaust Gas Temperature Out of Range Bank 1 Sensor 3 | Exhaust temperature control loop (temperature upstream particulate matter trap) comparison of actual and desired temperature upstream particulate matter trap (positive and negative control deviation) |
|
|
|
|
-- Check the Exhaust Gas Temperature Sensor 3 -G495-. Refer to EXHAUST GAS TEMPERATURE SENSOR 3 -G495-, CHECKING . |
| Exhaust temperature control loop (temperature upstream particulate matter trap) number of regeneration interruptions due to temperature upstream pm trap too high (>860°C) |
|
|
|
|||
| P2539 Low Pressure Fuel System Sensor Circuit | Low Pressure Fuel System Sensor |
|
|
|
-- Check the Low Fuel Pressure Sensor -G410-. Refer to LOW FUEL PRESSURE SENSOR -G410-, CHECKING | |
| P2541 Low Pressure Fuel System Sensor Circuit Low | Low Pressure Fuel System Sensor short to ground |
|
|
|
-- Check the Low Fuel Pressure Sensor -G410-. Refer to LOW FUEL PRESSURE SENSOR -G410-, CHECKING | |
| P2563 Turbocharger Boost Control Position Sensor Circuit Range/Performance | Turbo charger actuator position sensor physical signal range check |
|
|
|
-- Check the Charge Pressure Actuator Position Sensor -G581-. Refer to CHARGE PRESSURE ACTUATOR POSITION SENSOR - G581-, CHECKING . | |
| Turbo charger actuator position sensor position sensor signal in desired range during closed position learning |
|
|
|
|||
| P2564 Turbocharger Boost Control Position Sensor Circuit Low | Turbo charger actuator position sensor signal range check low |
|
|
|
-- Check the Charge Pressure Actuator Position Sensor -G581-. Refer to CHARGE PRESSURE ACTUATOR POSITION SENSOR - G581-, CHECKING . | |
| P2565 Turbocharger Boost Control Position Sensor Circuit High | Turbo charger actuator position sensor signal range check high |
|
|
|
-- Check the Charge Pressure Actuator Position Sensor -G581-. Refer to CHARGE PRESSURE ACTUATOR POSITION SENSOR - G581-, CHECKING . | |
| P2610 ECM/PCM Internal Engine Off Timer Performance | Engine Off timer plausibility counts of "Engine Off Timer" |
|
|
|
|
-- Replace the Engine Control Module (ECM) -J623- Refer to the Repair information for procedure. |
| P2626 O2 Sensor Pumping Current Trim Circuit/Open Bank 1, Sensor 1 | Oxygen sensor LSU check of compensation resistor wire circuit continuity |
|
|
|
|
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to OXYGEN SENSOR 1 BEFORE CATALYTIC CONVERTER -GX10-, CHECKING . |
| P2635 Fuel Pump "A" Low Flow/Performance (only Golf) | Electric Fuel Pump Speed Too Low |
|
|
|
-- Check the Fuel Delivery Unit -GX1- Refer to FUEL PUMP CONTROL MODULE - J538- / FUEL DELIVERY UNIT -GX1-, CHECKING | |
| Electric Fuel Pump Mechanical Fault |
|
|||||
| Electric Fuel Pump Speed Too Low |
|
|||||
| P26F4 Coolant Pump "C" Control Circuit/Open | Electric coolant pump open loop |
|
|
|
-- Check the Heater Support Pump -V488-. Refer to HEATER SUPPORT PUMP -V488-, CHECKING | |
| P26F5 Coolant Pump "C" Control Circuit Low | Electric coolant pump short circuit to ground |
|
|
|
-- Check the Heater Support Pump -V488-. Refer to HEATER SUPPORT PUMP -V488-, CHECKING | |
| P26F6 Coolant Pump "C" Control Circuit High | Electric coolant pump short circuit to battery |
|
|
|
-- Check the Heater Support Pump -V488-. Refer to HEATER SUPPORT PUMP -V488-, CHECKING | |
| P26F7 Coolant Pump "C" Supply Voltage Circuit | Electric coolant pump missing live signal |
|
|
|
-- Check the Heater Support Pump -V488-. Refer to HEATER SUPPORT PUMP -V488-, CHECKING | |
| P3007 Camshaft sensor no signal | Phase sensor for camshaft no signal |
|
|
|
|
-- Check the Camshaft Position Sensor -G40-. Refer to CAMSHAFT POSITION SENSOR -G40-, CHECKING . |
| U0001 High Speed CAN Communication Bus | High Speed CAN Communication Bus |
|
|
|
|
-- Check the CAN Bus. Refer to appropriate repair information. |
| U0002 High Speed CAN Communication Bus Performance | High Speed CAN Communication Bus Performance |
|
|
|
|
-- Check the CAN Bus. Refer to appropriate repair information. |
| U0028 Vehicle Communication Bus A | High Speed CAN Communication Bus Performance |
|
|
|
|
-- Check the CAN Bus. Refer to appropriate repair information. |
| U029D monitoring communication with NOx sensor | monitoring communication with NOx sensor |
|
|
|
-- Check the CAN Bus. Refer to appropriate repair information. | |
| U05A3 Invalid Data Received From Reductant Quality Module | Urea quality sensor communication temperature signal/communication quality signal |
|
|
|
|
-- Check the CAN Bus. Refer to appropriate repair information. |
| U059E monitoring communication with NOx sensor | monitoring communication with NOx sensor |
|
|
|
-- Check the CAN Bus. Refer to appropriate repair information. | |
| U0101 Lost Communication with TCM | Lost Communication with TCM |
|
|
|
-- Check TCM communication with a scan tool. If no TCM communication with scan tool and all othe r modules communicate, check TCM power and grounds. If OK, replace TCM Module. | |
| U0121 "Lost Communication With Anti-Lock Brake System (ABS) Control Module" | Lost Communication With Anti-Lock Brake System (ABS) Control Module |
|
|
|
-- Check ABS communication with a scan tool. If no ABS communication with scan tool and all othe r modules communicate, check ABS power and grounds. If OK, replace ABS Module. | |
| U0140 Lost Communication With Body Control Module | message from climate sensor 02 |
|
|
|
-- Check the CAN Bus. Refer to appropriate repair information. | |
| U0146 Lost Communication With Gateway "A" | Lost Communication With Gateway "A" |
|
--- |
|
|
-- Check Gateway communication with a scan tool. If no Gateway communication with scan tool and all othe r modules communicate, check Gateway power and grounds. If OK, replace Gateway Module. |
| U0155 "Lost Communication With Instrument Panel Cluster (IPC) Control Module" | Lost Communication With Instrument Panel Cluster (IPC) Control Module |
|
|
|
-- Check IPC communication with a scan tool. If no IPC communication with scan tool and all othe r modules communicate, check IPC power and grounds. If OK, replace IPC Module. | |
| U02A2 Lost Communication with Reductant Quality Module | Urea quality sensor communication to sensor |
|
|
|
|
-- Check the Reductant quality, refer to appropriate repair information. |
| U0302 Software Incompatibility with Transmission Control Module | Software Incompatibility with Transmission Control Module |
|
|
|
-- Check for correct software in ECM and TCM. If software is incorrect, reflash module with correct software. | |
| U0323 Software Incompatibility With Instrument Panel Control Module | check if sensor is mounted |
|
|
|
|
-- Refer to appropriate repair information for Instrument Cluster diagnosis. |
| U0402 Invalid Data Received From Transmission Control Module | Invalid Data Received From Transmission Control Module |
|
|
|
-- May have VIN error. Check VIN in each module for correct data | |
| U0415 "Invalid Data Received From Anti-Lock Brake System Control Module" | Invalid Data Received From Anti-Lock Brake System Control Module monitoring of communication with brake control module (message 07 / message 21) |
|
|
|
|
-- May have vehicle speed error. Using a scan tool, check for correct vehicle speed reading from wheel sensors in ABS module. If an ABS fault (DTC) exists, refer to the ABS Diagnosis in the Repair information. |
| Vehicle speed signal max. velocity exceeded |
|
|
||||
| Vehicle speed signal no signal |
|
|||||
| Vehicle speed signal out of range |
|
|||||
| U0422 Invalid Data Received From Body Control Module | monitoring of communication with instrument panel (only Golf) |
|
|
|
|
-- Refer to the Repair information for Instrument Cluster diagnosis. |
| U0423 "Invalid Data Received From Instrument Panel Cluster Control Module" | Invalid Data Received From Instrument Panel Cluster Control Module |
|
|
|
-- May have VIN error. Check VIN in each module for correct data | |
| U0447 Invalid Data Received From Gateway "A" | Lost Communication With Gateway "A" |
|
--- |
|
|
-- Check Gateway communication with a scan tool. If no Gateway communication with scan tool and all othe r modules communicate, check Gateway power and grounds. If OK, replace Gateway Module. |
| U05A3 Invalid Data Received From Reductant Quality Module | Urea quality sensor communication temperature signal |
|
|
|
|
-- Check the reductant quality. Refer to appropriate repair information. |
| Urea quality sensor communication quality signal |
|
|||||
| U1103 Production Mode active | ECM in production mode |
|
|
|
|
-- Mode can be deactivated with a factory scan tool or will automatically turn off after vehicle accumulates the first 100 miles of driving. |