Coolant Pump, Removing And Installing: Installing
Install In Reverse Order Of Removal. Note The Following:
CAUTION:
- Never perform a function test by pulling by hand on the coolant pump control valve.
- Do not engage or carry the coolant pump on the connector or the control valve.
- Do not operate the control valve.
- Replace the O-rings.
-- Clean and smooth the sealing surfaces of the O-rings.
-- Coat the new O-rings with coolant.
-- Install the toothed belt (adjust timing). Refer to TOOTHED BELT, REMOVING AND INSTALLING .
CAUTION:
- The coolant system must be bled using the Vehicle Diagnostic Tester after filling.
-- Fill and bleed the coolant circuit. Refer to TOOTHED BELT, REMOVING AND INSTALLING .