Battery, Disconnecting And Connecting: Connecting
- Tightening specifications: Refer to OVERVIEW - BATTERY for the Sedan. Refer to OVERVIEW - BATTERY for the Avant.
-- Disconnect the connector -2- from the Battery Monitoring Control Module -J367- -item 1-.
-- To connect, connect the battery ground cable terminal by hand to the battery negative terminal "-" and tighten nut -3-
-- Reconnect the connector to the Battery Monitoring Control Module -J367-.
When the battery is connected, the following steps must be performed:
- Activate the power window regulator one-touch up/down function. Refer to the Owner's Manual.
- Check DTC memories of all control modules and erase "Undervoltage" DTC if necessary using the Vehicle Diagnostic Tester.
NOTE:
After connecting the power supply, the ABS warning lamp may only go out after the vehicle has been driven a few yards.