-- Set-up requirements, refer to INSTALLED CALIBRATION TOOL : VAS6350 OVERVIEW 

-- Connect the Vehicle Diagnostic Tester.

Calibration Tool - Wheel Center Mountings:VAS6350/1 Installing: 

-- Check which hole circle the rims have.

-- Mount the Calibration Tool - Wheel Center Mountings:VAS6350/1  appropriately.

-- To do so, attach three wheel bolt adapters in the bolt circle to each Calibration Tool - Wheel Center Mountings:VAS6350/1  .

-- Attach paddles to both Calibration Tool - Wheel Center Mountings:VAS6350/1  and secure them with clamping screw.

-- Place the Wheel Center Mountings:VAS6350/1  onto the wheel bolts on the rear wheels.

The Calibration Tool - Wheel Center Mountings:VAS6350/1  are positioned by the "O rings" in the adapters and held in place.

Fig 1: Identifying Wheel Pick-Ups On Wheel Mounting Bolts At Rear Wheels
GWWN94-10685Courtesy of AUDI OF AMERICA, LLC
NOTE:

Attach The Calibration Tool - Wheel Center Mountings:VAS6350/1  Onto The Wheels So That Any Installed "Anti-Theft" Wheel Mounting Bolts Are Not Connected To The Calibration Tool - Wheel Center Mountings:VAS6350/1  .

-- Adjust paddle with aid of clamping screws so that they move freely just above the floor. Make sure the paddles move easily.

-- Install the Calibration Tool - Lane Change Calibration Tool:VAS6350/4  and align it, refer to Calibration Tool - Lane Change Calibration Tool .

DISTANCE MEASUREMENT: 

-- Switch on the Calibration Tool - Spacing Laser:VAS6350/2  with the ON  button.

The following display appears and the Calibration Tool - Spacing Laser:VAS6350/2  turns on.

Fig 2: Identifying Laser Display
GWWN94-10681Courtesy of AUDI OF AMERICA, LLC

-- Hold the Calibration Tool - Spacing Laser:VAS6350/2  -2- flush in the bracket on one side of the Calibration Tool - Lane Change Calibration Tool:VAS6350/4  . The Calibration Tool - Spacing Laser:VAS6350/2  -2- must sit securely on the bracket while doing so.

Fig 3: Ensuring Laser Beam From Distance Laser VAS 6350/2 Hits Lower, Enlarged Part Of Paddle
GWWN94-10684Courtesy of AUDI OF AMERICA, LLC

-- Make sure that the laser beam from Calibration Tool - Spacing Laser:VAS6350/2  -2- hits on the lower, enlarged part of paddle -1-.

If This Is Not The Case, Correct The Paddles Accordingly Using Clamping Screws On The Calibration Tool - Wheel Center Mountings:VAS6350/1  .

-- Use one hand to secure the Calibration Tool - Spacing Laser:VAS6350/2  in the bracket on the Calibration Tool - Lane Change Calibration Tool:VAS6350/4  while the laser beam is visible on the paddle.

-- Briefly press ON  button for distance measurement.

DISPLAY READOUT 

Fig 4: Identifying Display Readout
GWWN94-10682Courtesy of AUDI OF AMERICA, LLC

-- Note The Value Read Off.

-- Repeat measuring procedure in the same manner for the other rear wheel on the other side of the Calibration Tool - Lane Change Calibration Tool:VAS6350/4  .

The Distance Value Must Be The Same On Both Sides.

If Values Are Not Identical: 

-- Align the Calibration Tool - Lane Change Calibration Tool:VAS6350/4  long enough so that both sides are identical.

Pay attention when aligning the Calibration Tool - Lane Change Calibration Tool:VAS6350/4  , that the Calibration Tool - Linear Laser:VAS6350/3  from the Calibration Tool - Lane Change Calibration Tool:VAS6350/4  strikes the center of the Audi rings and the indicator of the level remains centered. If necessary, make further corrections.

Dimension Measurement -H- : 

-- Measure the height of the Calibration Tool - Lane Change Calibration Tool:VAS6350/4  , dimension -H- (top edge platform - floor).

Fig 5: Identifying Height Of Calibration Platform, Dimension -H-
GWWA91-11140Courtesy of AUDI OF AMERICA, LLC

Enter the height and distance dimensions into the Vehicle Diagnostic Tester in "millimeters".

PERFORMING CALIBRATION 

Vehicle Diagnostic Tester Is Attached.

-- Select Guided Fault Finding  .

-- Select "vehicle selection" from the menu for the corresponding vehicle data.

-- Using the GO TO  button, select the following menu points:

The Vehicle Diagnostic Tester Continues With The Calibrating Procedure From Here On.

WARNING:

Make Sure Light Does Not Reflect Off The Calibration Platform.