Home >> Audi >> 2013 >> TT RS >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 69 (Gears, Shafts - Direct Shift Automatic Transmission 02E AWD (Engine Code(S): CBRA, CCTA, CDMA & CETA) (Roadster) (As Of 08.2011)) >> 35 Gears, Shafts >> Specifications >> Fastener Tightening Specifications

Fastener Tightening Specifications

WARNING: This page is about a different variant/trim than selected.
Components Fastener Size Nm
Guard Plate - 32

Oil Pan - Tightening Specification and Sequence 

Fig 1: Identifying Oil Pan And Fasteners
GWWA37-0672Courtesy of AUDI OF AMERICA, LLC

-- Tighten the bolts -arrows- diagonally in steps to 16 Nm.

Direct Shift Gearbox (DSG) Transmission Mechatronic -J743- - Tightening Specification and Sequence 

Fig 2: Identifying Direct Shift Gearbox Bolt Tightening Sequence
GWWN35-10101Courtesy of AUDI OF AMERICA, LLC

-- Tighten the bolts in 2 steps in the following sequence: -1 through 10- :

-- Tighten bolts to 5 Nm.-- Tighten bolts an additional 90°.

Transmission Oil Pump - Tightening Specification and Sequence 

Fig 3: Transmission Oil Pump Tightening Specification And Sequence
GWWA37-10735Courtesy of AUDI OF AMERICA, LLC

-- Tighten bolts -arrows- in a diagonal sequence (different bolts depending on version):

Countersunk Bolts -A- :

-- Tighten countersunk bolts to 8 Nm.

Flat Head Bolts -B- :

-- Tighten flat head bolts in 2 stages as follows:

-- Tighten bolts to 8 Nm.-- Tighten bolts an additional 90°.

Transmission Oil Pump Cover -A- - Tightening Specification and Sequence 

Fig 4: Identifying Cap For Transmission Oil Pump And Fasteners
GWWA37-0670Courtesy of AUDI OF AMERICA, LLC

-- Tighten the bolts -arrows- diagonally in steps to 8 Nm.

Transmission Input Speed Sensor -G182- and Clutch Oil Temperature Sensor -G509-

Fig 5: Transmission Sensors And Bolts
GWWA37-0676Courtesy of AUDI OF AMERICA, LLC
A - Transmission input speed sensor and clutch oil temperature sensor.
 
B - Bolt
 
  • 10 Nm
C - Electrical connection