Connecting Piece With Coolant Thermostat
Special tools and workshop equipment required
- Hose Clip Pliers VAS 6362
Removing
-- Drain the coolant. Refer to COOLING SYSTEM, DRAINING AND FILLING .
-- Remove the ribbed belt from the tensioning element. Refer to RIBBED BELT .
-- Remove the bolt -1- and disconnect the exhaust gas recirculation (EGR) coolant thermostat and connection from the connection.
Ignore -2 and 3-.
-- Remove the coolant hose; to do this, loosen the hose clamp -1-.
-- Remove the bolts -arrows- and the coolant thermostat with the connection.
Installing
Install in reverse order of removal. Note the following:
- For the correct tightening specifications, refer to COOLANT PUMP AND COOLANT THERMOSTAT OVERVIEW .
Replace O-rings.
Secure all hose connections with the hose clamps appropriate for the model.
-- Clean the sealing surface.
-- Install the ribbed belt. Refer to RIBBED BELT .
-- Fill with coolant FILLING .