LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2010 >> S4 Automatic DCT >> Repair and Diagnosis >> External Pages >> Different car >> Section 1047 (Climate Control System (Service Information - Refrigerant R1234YF)) >> 87 Air Conditioning >> Refrigerant Circuit >> Pressure, Checking With Pressure Gauge >> Pressure Gauge Display

Pressure Gauge Display

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
GWWV87-1470Courtesy of AUDI OF AMERICA, LLC
  1. Temperature scale for Refrigerant R1234yf (CF3 CF = CH2 ) in °C
  2. Pressure scale in bar pressure
NOTE:

Pressure is measured in different units: 1 MPa (mega Pascal) corresponds to 10 bar (145 psi) positive pressure. 1 bar (14.5 psi) absolute pressure corresponds to 0 bar (0 psi) positive pressure and thus to the ambient pressure (atmospheric pressure).

This illustration shows the pressure gauge which shown the pressure on the low pressure side, the display here is in bar pressure gauge (can be recognized by the display "-1").

The pressure gauge may have one or more temperature scales next to the pressure scale. The R1234yf scale values are allocated respectively in the vapor pressure table. Since various refrigerants create different vapor pressures at the same temperature, each temperature scale is identified for the respective refrigerant.