Home >> Audi >> 2010 >> A4 2.0T >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 10 (Final Drive & Differential - Automatic Transmission 0B6 (Sedan)) >> 39 Final Drive, Differential >> Gear Oil >> Gear Oil, Draining And Filling >> Gear Oil, Draining And Filling, Transfer Case

Gear Oil, Draining And Filling, Transfer Case

WARNING: This page is about a different variant/trim than selected.

Special tools and workshop equipment required 

Work sequence:

NOTE:

General repair instructions. Refer to GENERAL REPAIR INFORMATION .

Clean working conditions for the automatic transmission. Refer to GUIDELINES FOR CLEAN WORKING CONDITIONS .

-- Place the Used Oil Collection and Extraction Unit SMN372500 under the transmission.

WARNING:

Danger of eye injury.

  • Wear protective eyewear.

-- Remove the locking bolt -arrow- on the side of the center differential housing.

Fig 1: Identifying Inspection Plug
GWWA39-0411Courtesy of AUDI OF AMERICA, LLC
NOTE:

Do not start the engine or tow the vehicle if there is no gear oil in the transmission.

-- Fill the transfer case with gear oil slowly and evenly over a period of least 5 minutes until gear oil flows out at the lower edge of the filling opening.

NOTE:

A filling time of at least 5 minutes is required so that the internal oil level between the center differential and oil fill space can equalize.

-- Repeat the filling process in steps every 15 seconds with 50 ml of gear oil until the transfer case stops accepting gear oil.

NOTE:

The inside of the transfer case is divided into several oil chambers. The waiting period is necessary to ensure they are all filled evenly.

Replace the drain plug and gasket.

-- Tighten the new sealing plug.

Tightening specification. Refer to OVERVIEW - CENTER DIFFERENTIAL .

NOTE:

It is not necessary to check the oil level again at this stage.