EGR Cooler Pump -V400-, REMOVING AND INSTALLING
WARNING: This page is about a different variant/trim than selected.
Removal
-- Carefully pull the engine cover off the 4 bolts one after the other -arrows-.
-- Drain the coolant. Refer to COOLANT, DRAINING AND FILLING .
-- Disconnect the connector -2-.
-- Remove the bolts -1-.
-- Remove the coolant hoses, to do so, loosen the hose clamps -arrows-.
-- Remove the EGR Cooler Pump -V400- with the engine lifting eye.
-- Remove the bolts -arrows- and remove the EGR Cooler Pump -V400- from the engine lift eyelet.
Installation
Install in reverse order of removal. Note the following:
- Tightening specification. Refer to EGR Cooler Pump -V400- OVERVIEW .
NOTE:
Secure all hose connections with hose clamps of the same type as those equipped by the factory .
-- Fill the coolant, refer to COOLANT, DRAINING AND FILLING .