Observe the Following when Working on the Reducing Agent Metering System:

WARNING:

The reducing agent can cause skin irritation.

  • Avoid contact with skin and eyes! Wear protective gloves!
  • If reducing agent should get on your skin, wash it off immediately with soap and water.
  • If reducing agent gets in your eye, rinse the eye for several minutes with water.
  • Never inhale or swallow the reducing agent!
  • Should you swallow any reducing agent, rinse your mouth, drink plenty of water and contact a doctor immediately.

Note the Following when Removing or Installing Any Components of the Reducing Agent Metering System:

Note the Following when Removing and Installing the Active or Passive Tank:

Reducing Agent, Automatic Regeneration 

WARNING:

Danger due to reducing agent leaking out.

  • To prevent large amounts of reducing agent from leaking out when opening the metering line, wait for the recirculation process to be completed. Refer to Reducing Agent, Automatic Regeneration, above.