Combination valve for secondary air injection, checking function and for proper seal
WARNING: This page is about a different variant/trim than selected.
Work sequence
- Disconnect pressure hose - 1 - at combination valve for secondary air injection.
NOTE:
- Ignore - arrows - in the illustration.
- Connect an appropriate assisting hose to combination valve.
- Blow into assisting hose using light pressure (do not use compressed air).
- Combination valve must be closed, it must not be possible to blow through.
- Blow into assisting hose using higher pressure (do not use compressed air).
- Combination valve must open, it must be possible to blow through.
If the switching point is not recognized:
- Replace combination valve: Left → Left combination valve for Secondary Air Injection (AIR), removing and installing , Right → Right combination valve for secondary air injection, removing and installing .