Turbocharger Vacuum Diaphragm, Checking
Special tools and workshop equipment required
- Hand Vacuum Pump VAS 6213
Test Conditions:
- Hose from exhaust turbocharger over wastegate bypass regulator valve -N75- must have continuity to vacuum diaphragm.
- Wastegate bypass regulator valve OK.
Work Procedure:
-- Remove the engine cover and air filter. Refer to Removal and Installation .
-- Connect VAS 6213 to vacuum diaphragm -arrow-.
-- Set the slide ring -1- on VAS 6213 to position -B- for "pressure".
The pressure must not exceed 750 mbar. If the pressure is exceeded, the vacuum diaphragm can be damaged.
-- Operate VAS 6213 several times and observe rods.
The linkage -A- must move approximately 300 mbar and be at approximately 700 mbar at end position.
Actuator lift is approximately 10 mm.
If pressure cannot be raised with VAS 6213 or pressure drops immediately, check VAS 6213 and connecting hoses for leaks. If no malfunction can be found: Replace vacuum diaphragm. Refer to TURBOCHARGER VACUUM DIAPHRAGM .