Initiating output Diagnostic Test Mode
WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2003 Audi S8, 2003 Audi A8, 2002 Audi S8, 2002 Audi A8, and 2001 Audi S8. However, it is still accessible from the selected car via links, so may be relevant.
- Press buttons -0- and -3- to select "output Diagnostic Test Mode" function 03.
Indicated on display:
Fig 1: V.A.G 1551 Scan Tool Display - Initiating Output Diagnostic Test Mode, Automatic Vertical Headlight Aim Control (1 Of 6)
- Press -Q- button to confirm input: Output Diagnostic Test Mode for automatic vertical headlight aim control is initiated immediately.
Indicated on display:
Fig 2: V.A.G 1551 Scan Tool Display - Initiating Output Diagnostic Test Mode, Automatic Vertical Headlight Aim Control (2 Of 6)
The headlights will be lowered until program is switched further or the lower end position is reached.
- Press --> button.
Indicated on display:
Fig 3: V.A.G 1551 Scan Tool Display - Initiating Output Diagnostic Test Mode, Automatic Vertical Headlight Aim Control (3 Of 6)
The headlights will be raised until program is switched further or the upper end position is reached.
- Press --> button.
Indicated on display:
Fig 4: V.A.G 1551 Scan Tool Display - Initiating Output Diagnostic Test Mode, Automatic Vertical Headlight Aim Control (4 Of 6)
Warning symbol (auto. vert. headlight aim control) is indicated in the center display of the instrument cluster.
Indicated on display:
Fig 5: V.A.G 1551 Scan Tool Display - Initiating Output Diagnostic Test Mode, Automatic Vertical Headlight Aim Control (5 Of 6)
- Press --> button.
The tester returns to the "Select function" mode.
Indicated on display