Recirculation Control Motor Test
Special Tools Required
Backprobe Set 07SAZ-001000A
NOTE:
Before testing the motor, check for climate control DTCs (see HOW TO CHECK FOR DTCS WITH THE HDS
).
- Disconnect the 7P connector from the recirculation control motor.NOTE: Incorrectly applying power and ground to the recirculation control motor will damage it. Follow the instructions carefully.
- Connect battery power to terminal No. 1 of the recirculation control motor, and ground terminal No. 2; the recirculation control motor should run, and stop at Fresh. If it does not, reverse the connections; the recirculation control motor should run, and stop at Recirculate. When the recirculation control motor stops running, disconnect battery power immediately.
- If the recirculation control motor did not run in step 2, remove it, then check the recirculation control linkage and door for smooth movement.
- If the linkage and door move smoothly, replace the recirculation control motor (see RECIRCULATION CONTROL MOTOR REPLACEMENT ).
- If the linkage or door sticks or binds, repair them as needed.
- If the recirculation control motor runs smoothly, go to step 4.
- Measure the resistance between terminals No. 5 and No. 7 of the recirculation control motor. It should be between 4.2 and 7.8 kΩ.
- Reconnect the recirculation control motor 7P connector, then turn the ignition switch to ON (II).
- Using the backprobe set (07SAZ-001000A), measure the voltage between terminals No. 3 and No. 5.
Fresh: About 1.0 V
Recirculate: About 4.0 V
- If either the resistance or voltage readings are not as specified, replace the recirculation control motor (see RECIRCULATION CONTROL MOTOR REPLACEMENT ).