Rewriting the ODO Data on a New Gauge Control Module
NOTE:
- If the HDS retrieves the ODO data from the gauge control module, the ODO value on the multi-information display will appear as "- - -", making the ODO function unusable, and the HDS will be unable to retrieve additional ODO values.
- Rewriting is not possible on a gauge control module that does not communicate.
- Obtain a new gauge control module before starting the rewriting process.
- Before replacing the gauge control module, connect the HDS to the data link connector.
- Select GAUGES from the BODY ELECTRICAL SYSTEM SELECT MENU display.
- Select "Gauge Control Module Replacement (ODO rewrite)" from the ADJUSTMENT MENU, and follow the instructions on the display to retrieve the ODO value.
- Replace the gauge control module.