A/C Compressor Oil [2016, B5254T12]
When replacing components, the following oil volume must be found in the new components or shall be filled in the system through the service valve, except for the compressor, see below
| Quantity of oil | Dryer, integrated in the condenser | Dryer, External |
| Receiver drier | 0 cm3 | 20 cm3 |
| Evaporator | 50 cm3 | 50 cm3 |
| Condenser | 30 cm3 | 30 cm3 |
| Tube | 10 cm3 | 10 cm3 |
| Hose | 20 cm3 | 20 cm3 |
Oil return when reusing compressor
- measure the volume of the oil drained from the compressor
- Replace the volume of drained oil according to the tables below:
| Reusing the compressor | |
| Drained oil | Filling with oil |
| =70 cm3 | Replace the volume of drained oil with the corresponding quantity |
| <70 cm3 oil | fill with 70 cm3 of oil. |
Oil return for new compressor
- Drain the old compressor of oil, and measure the amount
- Drain the new compressor of oil (the amount may be below specified value since it is not possible to drain all oil from the compressor)
- Use the table below to fill the new compressor with the right amount of oil
| New compressor | |
| Drained oil | Filling with oil |
| =70 cm3 | replace the drained oil volume with the same amount that was drained from the old compressor. |
| <70 cm3 oil | fill with 70 cm3 of oil. |