Bypass Valve, A/C Cooling [2016-2020, B4204T28 | 2020, B4204T39]: Removal
NOTE:
Removal steps in this procedure may contain installation details.
Remove Inverter Generator Module (IGM), refer to: INVERTER GENERATOR MODULE
Remove the screws.
Torque: IGM, to Body frame, 13Nm
Release the lock.
Fold marked part aside.
Release the lock.
Fold marked part aside.
Release the lock.
Fold marked part aside.
Use: Pliers
Loosen the clip.
Use: Pliers
Loosen the clip.
Release the connector's catch.
Disconnect the connector.
Fold marked part aside.
Loosen the screws.
Torque: M5, 5Nm
Loosen the hose clamp.
Undo the hose from the connection.
Fold marked part aside.
Lift the marked component forward.
CAUTION:
Note the routing of the lines and hoses.
CAUTION:
Note the position of the components before removal.
Loosen the hose clamps.
Undo the hoses from the connections.