Checking The Component And Cable
- Ignition off.
Check the cable between central electronic module (CEM) connector terminal #D16 and ignition switch connector terminal #1. Check for a short-circuit to supply voltage.
The voltage must be 0 V if the key is in position 0 or I.
Other information:
- see CONNECTING THE BREAKOUT BOX
- -2004: SIGNAL SPECIFICATION
- 2005-: SIGNAL SPECIFICATION
- For -2004, see: CENTRAL ELECTRONIC MODULE (CEM), REPLACING .
- For 2005-, see: CENTRAL ELECTRONIC MODULE (CEM), REPLACING .
- see CHECKING WIRING AND TERMINALS
Were any faults found in the cable?
- YES
Refer to VERIFICATION
- NO
Refer to REPLACING THE COMPONENT