Checking The Component And Cable
- Ignition off.
Check the cable between central electronic module (CEM) connector terminal #D8 and the ignition switch X-supply (terminal #6). Check for an open-circuit. Check for a short-circuit to ground.
Switch on the ignition. The voltage must be the same as battery voltage if the key is in position I or II.
Other information:
- see CONNECTING THE BREAKOUT BOX
- -2004: SIGNAL SPECIFICATION
- 2005-: SIGNAL SPECIFICATION
- For -2004, see: CENTRAL ELECTRONIC MODULE (CEM), REPLACING .
- For 2005-, see: CENTRAL ELECTRONIC MODULE (CEM), REPLACING .
- see CHECKING WIRING AND TERMINALS
Is the voltage OK?
- YES
Refer to VERIFICATION
- NO
Refer to REPLACING THE COMPONENT