Checking The Component And Cable
- Ignition off.
Check the cable between control module terminal #1B and ignition switch terminal #S (#3). Check for an open-circuit. Check for a short-circuit to ground.
Remedy as necessary.
Other information:
- The voltage must be the same as battery voltage if the key is in position 0, I, II or III
- For -2004, see: CENTRAL ELECTRONIC MODULE (CEM), REPLACING .
- For 2005-, see: CENTRAL ELECTRONIC MODULE (CEM), REPLACING .
- To connect the breakout box to the control module, see CONNECTING THE BREAKOUT BOX
- -2004: SIGNAL SPECIFICATION
- 2005-: SIGNAL SPECIFICATION
- see CHECKING WIRING AND TERMINALS. PERMANENT FAULT .
Was a fault detected?
- YES
Refer to VERIFICATION
- NO
Refer to REPLACING THE COMPONENT