Checking Wiring
Check the cable between central electronic module (CEM) connector #1B and ignition switch S-supply #3 for an intermittent open-circuit according to OPEN-CIRCUIT, INTERMITTENT FAULTS and for a short-circuit to ground according to SHORT-CIRCUIT TO GROUND, INTERMITTENT FAULTS .
Other information
- The voltage must be the same as battery voltage if the key is in positions 0, I, II or III.
- For -2004, see: CENTRAL ELECTRONIC MODULE (CEM), REPLACING .
- For 2005-, see: CENTRAL ELECTRONIC MODULE (CEM), REPLACING .
- To connect the breakout box, see CONNECTING THE BREAKOUT BOX
- -2004: SIGNAL SPECIFICATION
- 2005-: SIGNAL SPECIFICATION