Checking Components And Wiring

Check the signal cable for alarm output P1. Check between accessory control module terminal #B16 and the alarm unit connector. Check for a short-circuit to supply voltage.

Remedy as necessary.

Other information: 

Fig 1: Accessory Electronic Module Ground Terminals
GLL106164Courtesy of VOLVO CARS CORPORATION
Fig 2: Identifying Ohm Meter