Inspection & Adjustment
| 951 2986 Measurement sensor (Part of 9512985) Tool number: 951 2986 Tool description: Measurement sensor (Part of 9512985) Tool boards: EU99 |
|
| 951 2985 Measuring tools Tool number: 951 2985 Tool description: Measuring tools Tool boards: 20 |
|
| 951 2775 Cylinder leak tester Tool number: 951 2775 Tool description: Cylinder leak tester Tool boards: 21 |
| Materials | |
|---|---|
| Designation | Part number |
| Universal oil | 1161657 |
CHECK
Use: Universal oil, 1161657
Refer to: Special Tool: 951 2986
Make sure that the component moves freely between the end positions.
Refer to: Special Tool: 951 2985
Refer to: Special Tool: 951 2775
Make sure that the component moves freely between the end positions.
Repeat the following steps until the component moves freely. Some minimal binding is permitted.
- Adjust to the specified value.
- Close the shutoff valve.
- Remove the hose.
- Check that the pressure-drop remains within the specified values.
- Refer to graph in the illustration.
- See information about wastegate valve. Refer to: WASTEGATE VALVE
- Refer to graph in the illustration.
If the specified pressure is exceeded repeat the steps.
Note the value.
- Refer to graph in the illustration.
- Refer to graph in the illustration.
- See information about wastegate valve. Refer to: WASTEGATE VALVE
If the specified pressure is exceeded repeat the steps.
Note the value.
Calculate the average value.
Follow the instructions for wastegate valve. Refer to: WASTEGATE VALVE
If the average value is not according to specifications, adjust the stroke.
Turn the adjusting screw counter-clockwise to increase stroke. Turn the adjusting screw clockwise to decrease stroke.
One revolution corresponds to approx. 1 mm stroke.
Take extra care when handling the component.
- Loosen the nut.
- Adjust to specified average value.
See information about wastegate valve. Refer to: WASTEGATE VALVE
Take extra care when handling the component.
Torque: Pressure regulator, lock nut adjuster rod, 7Nm
Repeat the method to verify that the average value is according to specifications.