Checking The Wires
Check and measure the wire between combined instrument 4 and engine control module connector B 46 for an open circuit as described in, see SHORT-CIRCUIT TO GROUND, PERMANENT FAULTS , and a short circuit to voltage supply as described in SHORT-CIRCUIT TO SUPPLY VOLTAGE. PERMANENT FAULTS .
Additional information:
- To connect the test box, see CONNECTING THE DRIVER INFORMATION MODULE (DIM) TEST BOX .
Is there a fault?
- YES
Refer to VERIFICATION
- NO
FAULT NOT FOUND: Troubleshooting has been completed.