Checking The Wiring
Check the cable between fuse 11D/4 terminal #2 and relay 2/80 terminal #5. Check the cable between relay 2/80 terminal #3 and the left and right upper lamp housing switches terminal #3. Check these cables for a short-circuit to supply voltage according to SHORT-CIRCUIT TO SUPPLY VOLTAGE. PERMANENT FAULTS .
Remedy as necessary.
Other information:
- For further information about signals and other values, see SIGNAL SPECIFICATION
- To connect the breakout box, see CONNECTING THE BREAKOUT BOX .
- To access the integrated relay/fusebox in the cargo compartment, see RELAY/FUSE BOX CARGO COMPARTMENT/REAR ELECTRONIC MODULE (REM), REPLACING .